2 year Warranty
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
The accelerometer is designed for quick measurements of an imbalance in machines and the examination of bearings and gears. The accelerometer is also frequently used to evaluate the state of small electronic motors. Meter can only be used for realtime measurement, no memory storage.
- Vibration Acceleration: 0.01 ... 199.9 m/s2 (peak value)
- Vibration Speed: 0.01 ... 199.9 mm/s (effective)
- Vibration Displacement: 0.001 ... 1.999 mm (peak-peak)
- Accuracy: ±5%, ±2 Digits (20 Hz ... 1 KHz) / ±10%, ±2 Digits (10 Hz ... 20 Hz)
- Frequency: Accel. and Vel. 10 Hz ... 1 kHz, Displacement 10 Hz ... 500 Hz
- Frequency range: 10 Hz ... 1 kHz
- Needle probes: 10mm / 0.39" // 45mm / 1.77"
- incl. ISO Calibration Certificate
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
- incl. ISO Calibration Certificate
The vibration analyzer is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems.
With the help of this vibration analyzer, the actual state can easily be determined on site.
Thus, corresponding changes can be made directly on site after the measurement.
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Easy to handle and battery operated
- Standard probe: 10mm
- incl. ISO Calibration Certificate
The vibration analyzer is suitable for relative measurements on various machines. With the 45 mm long needle probe, you can access hard-to-reach places in machines and motors. For this reason, this vibration analyzer is used for rapid measurement of imbalance and for checking bearing and gear conditions.
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
- incl. ISO Calibration Certificate
PCE-PCO 2 is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature, dew point and relative humidity.
- PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
- Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Temp. measuring range: 0 ... +50 °C / +32 ... +122 °F
- Humidity measuring range: 0 ... 100 % RH
- Built-in camera for image and video recording
- Free software download on PCE Software web page
Calibration and Recalibration not available in the USA
PCE-TDS 100HS is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 100, 20 … 108 mm (approx. 3/4 … 4")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase Portable Power Analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase Portable Power Analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage