Description

Ultrasonic flowmeter with 32 GB data memory / measuring range ±32 m/s / 
reproducibility ±0.5 % of measured value / different measuring probes / alarm limit values /
2.8 " LC display / for all media 

The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the Clamp-on Ultrasonic Flow Meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the Clamp-on Ultrasonic Flow Meter. The installation aid graphically displays the signal quality of the Clamp-on Ultrasonic Flow Meter. In addition, it is graphically displayed whether the sensors of the Clamp-on Ultrasonic Flow Meter are positioned at the correct distance from each other. To carry out flow measurements with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The Clamp-on Ultrasonic Flow Meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob. 

During a measurement, it is possible to record the measured values via the data logger function of the Clamp-on Ultrasonic Flow Meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the Clamp-on Ultrasonic Flow Meter. A memory point of the Clamp-on Ultrasonic Flow Meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the Clamp-on Ultrasonic Flow Meter. 10 million measuring points can be stored on the Clamp-on Ultrasonic Flow Meter.

With the optional software, the recorded measured values can be read out from the Clamp-on Ultrasonic Flow Meter. For analysis, the measured values from the Clamp-on Ultrasonic Flow Meter can be displayed in tabular and graphic form. For further processing of the measured values from the Clamp-on Ultrasonic Flow Meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the Clamp-on Ultrasonic Flow Meter can be set via the software. A live view of the measured values from the Clamp-on Ultrasonic Flow Meter is also possible with the software. 

In order to determine the amount of heat with the Clamp-on Ultrasonic Flow Meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the Clamp-on Ultrasonic Flow Meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the Clamp-on Ultrasonic Flow Meter can determine the amount of heat. If required, the Clamp-on Ultrasonic Flow Meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the Clamp-on Ultrasonic Flow Meter is used, for example, in the inspection of heating systems.

The LC colour display of the Clamp-on Ultrasonic Flow Meter has a size of 2.8" and is therefore easy to read. 

PCE-TDS 200 ML SENSOR
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the Clamp-on Ultrasonic Flow Meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.

PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the Clamp-on Ultrasonic Flow Meter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.

Highlights

- Measuring range ±32 m/s
- USB-C interface for data transfer 
- Optional software for analysing the measured values
- Reproducibility ±0.5 % of measured value 
- Heat quantity measurement
- Data memory for 10 million measuring points
- individually adjustable alarm limits


Specification

  
Flow measurement 
Measuring range±32 m/s
Accuracy0,001 m/s
GenauigkeitDN ≥50 mm: ±1.5 % rdg. for velocities > 0.3 m/s
 DN <50 mm: ±3.5 % rdg. for velocities > 0.3 m/s
Reproducibility±0.5 % of measured value
  
PCE-TDS 200 M SENSORSensor pair
Pipe diameterDN 50 ... 700 / 57 ... 720 mm
Temperature resistance-30 ... 160 °C
Dimension45 x 30 x 30 mm
  
PCE-TDS 200 L SENSOR 
Pipe diameterDN 300 ... 6000 mm
Temperature resistance-30 ... 160 °C
Dimension91 x 52 x 44 mm
 
  
Measuring methodZ, V, N, W
Medium- water
 - sea water
- oil
 - crude oil
 - methanol
 - ethanol
 - diesel
 - petrol
 - petroleum
 - user defined
 (manual input of the sound velocity from the medium)
  
All liquids with an impurity<5 %
Pipe material- copper CU
 - steel FE
 - stainless steel VA
 - aluminium AL
 - brass ME
 - cast iron CI
 - iron FE
 - nickel NI
 - titanium TI
 - zink ZI
- acrylic AC
 - polyethylene PE
 - polypropylene PP
 - polyvinyl chloride PVC
 - nylon NY
 - user defined
(manual input of the transversal sound velocity
 of the pipe material)
  
Inner pipe lining- no lining
 - user defined
 - epoxy resin
 - rubber
 - mortar
 - polystyrene PS
 - polyethylene PE
 - polytetrafluoroethylene PTFE
- polyurethane PU
 - polypropylene PP
 - user defined
 (manual input of the longitudinal sound velocity
 of the inner lining of the pipe)
  
Measurement parametersflow velocity, volume flow and volume
Units (dimensions)mm, in
Units (flow velocity)m/s, ft/s
Units (volume flow)m³, l, gal, igl, mgl, cf, bal, ib, ob
Time specificationseconds, minutes, hours, days
Units (volume)m³, l, gal, igl, mgl, cf, bal, ib, ob
  
Temperature measurement 
Measuring rangeAccuracy
Type B: 600 ... 1800 °CType B: ±(0.5 % + 3 °C)
Type E: -100 ... +900 °CType E: ±(0.4 % + 1 °C)
Type J: -100 ... 1150 °CType J: ±(0.4 % + 1 °C)
Type K: -100 ... +1370 °CType K: ±(0.4 % + 1 °C)
Type N: -100 ... + 1150 °CType N: ±(0.4 % + 1 °C)
Type R: 0 ... 1700 °CType R: ±(0.5 % + 3 °C)
Type S: 0 ... 1500 °CType S: ±(0.5 % + 3 °C)
Type T: -100 ... +400 °CType T: ±(0.4 % + 1 °C)
  
Resolution 0.1 °C
Connectable thermocouplesB, E ,J ,K ,N ,R ,S ,T
Measuring parametersflow rate, volume flow, volume, temperature,
 Heat output and heat quantity
Units (temperature) °C / °F
Units (heat quantity)K, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu
Units (heat output)W, kW, MW, J/h, kJ/h MJ/h, Btu/h, kBtu/h, MBtu/h
Cost displayEUR, Pound, USD, Turkish Lira, Zloty, Yen

Further specifications
2.8" LCD2,8“ LCD
Menumetrisch / imperial
Menu languagesGerman, English, French, Spanish,
 Italian, Dutch, Portuguese, Danish, Turkish, Polish, German
 Turkish, Polish, Russian, Chinese, Japanese
Operating and storage conditions Temperature: -20 ... +65 °C
 Humidity: 10 ... 95 % r. h., non-condensing
Data logger32 GB memory capacity / 10 million measuring points
 UnterfaceUSB (for online measurement, readout of the internal memory
 memory and for recharging the battery)
Protection classIP52
Power supply InternalInternal: LiPo battery (3.7 V, 2500 mAh)
 External: USB 5 VDC, 500 mA
Operating timeapprox. 10 h
Dimensions165 x 85 x 32 mm
Weight255 g
  

Delivery Scope

1 x Clamp-on Ultrasonic Flow Meter PCE-TDS 200 ML-ICA
1 x Flow sensors PCE-TDS 200 M SENSOR (pair)
1 x flow sensors PCE-TDS 200 L SENSOR (pair)
2 x 5 m connection cable 
2 x detachable cable ties
1 x power supply unit
1 x USB-C cable
1 x ultrasonic contact gel 
1 x PCE measuring tape
1 x plastic case
1 x instruction manual