- Radius: 16.5 … 30mm
- Only for PCE-900, PCE-1000 and PCE-2000
PCE-900 Surface Testing for metals
9 materials pre-calibrated / Conversion into 6 different hardness scales
/ Type D impact probe
The Leeb Hardness Tester PCE-900 measures the hardness of nine different metals using the Leeb rebound method.
This means that with the hardness tester a firing pin bounces on a metallic surface and the intensity of the rebound is used as an indicator of the material hardness.
The hardness tester PCE-900 measures the metal hardness in 6 different hardness scales, including: Rockwell, Vickers, Leeb, Brinell and Shore.
A distinction is made between Rockwell B and C when measuring in the Rockwell scale.
The Leeb hardness tester PCE-900 comes with a type D impact probe as standard. This probe can be used for many measurements. Via the optional software, the measured values can be transmitted live to the PC. This makes the PCE-900 Leeb hardness tester an important instrument in the field of material inspection in goods control.
Measuring range | 200 ... 900 HL |
Measuring accuracy | ± 0.8% at HLD=900 |
Materials | 9 common material presets |
Hardness scales | Leeb: HL Rockwell C: HRC Rockwell B: HRB Brinell: HB Vickers: HV Shore: HSD |
Display | 12.5 mm / 0.5" LCD with backlight |
Impact probe | Type D |
Memory | 50 data sets |
Interface | RS-232 |
Power supply | 4 x 1.5V AAA batteries |
Environmental conditions | Operating temperature: -10 ... 50°C / 14 ... 122°F Storage temperature: -30 ... 60°C / -22 ... 140°F Relative humidity: < 90% |
Dimensions | 142 x 77 x 40 mm / 5.59 x 3.03 x 1.58 in |
Weight | Device weight: ca. 130 g / < 1 lb Probe weight: 75 g / < 1 lb |
Cable length | ca. 1.2 m / 3.9 ft |
ex. VAT, ex. delivery costs
Consisting of:
HZ12.5-17 Mounting adapter concave, 12.5 … 17 mm (inside)
HZ11-13 Mounting adapter concave, 11 … 13 mm (inside)
HZ16.5-30 Mounting adapter concave, 16.5 … 30 mm (inside)
Z10-15 Mounting adapter convex, 10 … 15 mm (outside)
Z14.5-30 Mounting adapter convex, 14.5 … 30 mm (outside)
Z25-50 Mounting adapter convex, 25 … 50 mm (outside)
HK11-13 Ball mounting adapter ball, 11 … 13 mm (inside)
HK12.5-17 Ball mounting adapter ball, 12.5 … 17 mm (inside)
HK16.5-30 Ball mounting adapter ball, 16.5 … 30 mm (inside)
K14.5-30 Mounting adapter ball, 14.5 … 30 mm (outside)
K10-15 Mounting adapter ball, 10 … 15 mm (outside)
ex. VAT, ex. delivery costs
ISO recalibration for vibration meters is often required to comply with DIN ISO 9000.
If your calibration certificate expires, you can easily return your meter for re-calibration. We carry out the calibration and send you the device with a new calibration certificate.