Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!
Technical Specification of the Gas Leak Detector | |||||
Model 300 Series | |||||
As Model 200 Series, in addition: | |||||
Alarm function | "High", "Low", Mute | ||||
Alarm output | Transistor output, 150-mA max | ||||
Low Alarm, High Alarm & Control | |||||
Analog output | 0... 5V | ||||
Location ID | Storage of the measuring location | ||||
Model 200, 300 and 500 Series | |||||
Power supply | 12V DC | ||||
Rechargeable battery | Lithium-Polymer 12V DC / 2700 mAh | ||||
Charger | 12.6V 2 A | ||||
Charging voltage | 12.6V | ||||
Charging time | 2... 3 hours | ||||
Lifecycle | > 500 charges | ||||
Housing | PC & ABS / IP20 & NEMA 1 | ||||
Dimensions (incl. opt. sensorsavailable) | 7.7 x 4.8 x 2.1 in / 195 x 122 x 54 mm | ||||
Weight | < 1 lb / 460 g (with battery) | ||||
Approvals | EN 50082-1: 1997, EN 50081-1: 1992, CE | ||||
Optional accessories for the gas detector: Sensors: | |||||
Gas Code | Meas. (ppm) | Min. (ppm) | Meas. (ppm) | Resolution. (ppm) | Temp. °C/ humidity. % |
GSS sensors (semiconductor sensors): | |||||
Ozone (O3) OZU | 0 ... 0.15 | 0.001 | < ±0.005 % | 0.001 | 0 ... +40 10 ... 90 |
Ozone (O3) OZL | 0 ... 0.5 | 0.001 | < ±0.008 0 ... 0.1 | 0.001 | 0 ... +40 10 ... 90 |
Ozone (O3) OZG | 0 ... 10 | 0.01 | < ±0.1 0...1 | 0.01 | 0 ... +40 10 ... 90 |
Hydrogen (H2) HA | 0 ... 5000 | 5 | < ±10 % | 1 | 0 ... +40 10 ... 90 |
Chlorine (CL2) ECL | 0 ... 10 | 0.1 | < ±10 % | 0.01 | 0 ... +40 10 ... 90 |
Ozone (O3) Leakage finder OZK | 0.01 | 0.01 | 0 ... +40 10 ... 90 | ||
Methane (CH4) MT | 0 ... 10,000 | 10 | < ±15 % | 1 | 0 ... +40 10 ... 90 |
NMHC VN | 0 ... 25 | 0.1 | < ±10 % 0.1 ... 25 | 0.1 | 0 ... +40 10 ... 90 |
Tetrachlorethylene (C2CL4) PE | 0 ... 200 | 1 | < ±5 0 ... 50 | 1 | 0 ... +40 10 ... 90 |
(VOC) VM | 0 ... 25 | 0.1 | ±10 % | 0.1 | 0 ... +40 10 ... 90 |
(VOC) VP | 0 ... 500 | 1 | ±10 % | 1 | 0 ... +40 10 ... 90 |
GSE sensors (electrochemical sensors): | |||||
Ammonia (NH3) ENG | 0 ... 100 | 0.2 | ±10 % | 0.1 | 0 ... +40 10 ... 90 |
Carbon monoxide (CO) ECN | 0 ... 100 | 0.1 | < ±1 0... 10 | 0.1 | 0 ... +40 10 ... 90 |
Carbon monoxide (CO) ECM | 0 ... 25 | 0.02 | < ±0.5 0 ... 5 | 0.01 | 0 ... +40 10 ... 90 |
Formaldehyde (CH2O) EF | 0 ... 10 | 0.01 | < ±0.05 0 ... 0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur- hydrogen (H2S) EHS | 0 ... 10 | 0.01 | < ±0.05 0 ...0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur- hydrogen (H2S) EHT | 0 ... 100 | 0.2 | < ±0.5 0 ... 5 | 0.1 | 0 ... +40 10 ... 90 |
Nitrogen dioxide (NO2) ENW | 0 ... 1 | 0.002 | < ±0.02 0 ... 0.1 | 0.001 | 0 ... +40 10 ... 90 |
Sulfur dioxide (SO2) ESO | 0 ... 10 | 0.01 | < ±0.05 0 ... 0.5 | 0.01 | 0 ... +40 10 ... 90 |
Sulfur dioxide (SO2) ESP | 0 ... 100 | 0.2 | < ±0.05 0 ... 0.5 | 0.1 | 0 ... +40 10 ... 90 |
NDIR sensors (infrared sensors): | |||||
Carbon dioxide (CO2) CD | 0 ... 2000 | 2 | < ±5 % (of the display) | 1 | 0 ... +40 10 ... 90 |
Carbon dioxide (CO2) CE | 0 ... 5000 | 5 | <± 5 % (of the display) | 1 | 0 ... +40 10 ... 90 |
Carbon dioxide (CO2) CF | 0 ... 5 % | 0.02 % | <± 5 % (of the display) | 0.01 % | 0 ... +40 10 ... 90 |
PID sensors (photoionization detector sensors): | |||||
VOC PDL | 0 ... 20 | 0.01 | < ±10 % | 0.01 | 0 ... +40 10 ... 90 |
VOC PDH | 0 ... 1000 | 0.2 | < ±10 % | 0.1 | 0 ... +40 10 ... 90 |
Combi sensors: | |||||
CO2 CO PID Code: MS2 | 0 ... 2000 0 ... 100 0 ... 25 | 2 0.1 0.01 | ±40 + 3 % ±10 % 1 ...100 ±10 % of result | 1 0.1 0.01 | 0 ... +40 10 ... 90 |
CO2 CO Code: MS1 | 0 ... 2000 0 ... 100 | 2 0.1 | ±40 + 3 % ±10 % 1 ...100 | 1 0.1 | 0 ... +40 10 ... 90 |
1 x Basic device AQ-300
1 x 12V DC 800-mA AC/DC Power
Supply Unit
1 x Battery Pack 12V
1 x Operating
instructions
Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!
Optional
accessories forGas Detector AQ series:
Sensors:
< ±0.008
0 ... 0.1
0.0010 ... +40Ozone (O3)
Leckfin. OZK