Measuring range pH | -2.000 ... 19.999 pH |
Resolution | 0.1 / 0.01 pH |
Accuracy | electrode: ±0.02 pH |
Input current | ≤1×10^-12 A |
Input resistance | ≥3×10^12 Ω |
Measurement stability | ±0.01 pH/3h |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Measuring range mV | -1999.9 ... 1999.9 mV |
Resolution | 1 mV |
Accuracy | ±0.03 % of measuring range |
Measuring range temperature | -10 ... 110 °C / 14 ... 230 °F |
Resolution | 0.1 °C |
Accuracy | 5 ... 60 °C (41 ... 140 °F): ±0.4°C |
rest: ±0.8 °C | |
Measuring range conductivity | 0 ... 19.99 µS/cm |
20.0 ... 199.9 µS/cm | |
200 ... 1999 µS/cm | |
2.00 ... 19.99 mS/cm | |
20.0 ... 1999.9 mS/cm | |
Resolution | 0.01 / 0.1/ 1 μS/cm, 0.01 / 0.1 mS/cm |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range TDS | 0 ... 100 g/l |
Resolution | 0.001 mg/l |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range salinity | 0 ... 100 ppt |
Resolution | 0.1 ppt |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range resistance | 0 ... 100 MΩ cm |
Resolution | 0.001 / 0.01 / 0.1 / 1M Ω·cm |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Data memory | 300 pH measuring points |
300 conductivity measuring points | |
Content of a memory point | date and time, measured value with unit and temperature |
Display | 7" touchscreen |
Resolution | 1024 x 600 pixels |
Interfaces | USB A |
USB B | |
Bluetooth | |
Power supply | Primary: 230 ... 240 V / 50 Hz |
Secondary: 12 V DC / 1 A | |
Operating conditions | 5 ... 35 °C / 41 ... 95 °F, < 85 % RH not condensing |
IP protection class | IP 54 |
Dimensions | 175 × 220 × 40 mm / 68.9 x 86.6 x 15.7" |
Weight | ca. 310 g / 10.9 lb |
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Electrode for measuring the redox potential (ORP) - Range: ±2000 mV - Electrode structure is silver-silver/chloride gel - Measuring temp from 0 to 100 °C (32 to 212 °F) - Body length 150 mm
ex. VAT, ex. delivery costs
Replacement paper rolls for Bluetooth printersPackage content: 4 pieces
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
pH electrode especially for wine, beer and other liquids with low conductivity
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
pH electrode especially for soil, mud and slurry
ex. VAT, ex. delivery costs
pH electrode especially for beer, blood and milk products
ex. VAT, ex. delivery costs
Calibration Solution pH4 and pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
ex. VAT, ex. delivery costs
Special pH probe:
ex. VAT, ex. delivery costs
Calibration Solution pH4, pH7 and pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
-pH 4, pH 7 and pH 10
ex. VAT, ex. delivery costs
Calibration Solution pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
ex. VAT, ex. delivery costs
Calibration Solution pH7. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
ex. VAT, ex. delivery costs
Calibration Solution pH4. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.