ex. VAT, ex. delivery costs
pH measurement |
|
Measurement range | 0 ... 14.0 pH |
Resolution | 0.01 pH |
Accuracy | ±0.02 pH + 2 digits |
Calibration | 3 points (pH 4, pH 7, and pH 10) |
Temperature compensation | Automatic with additional temperature sensor (0 ... 60 ºC / 32 ºF ... 140 ºF) or manual (0 ... 100 ºC / 32 ºF ... 212 ºF) |
Redox measurement (optional) | |
Measurement range | 1999 ... 0 ... 1999 mV |
Resolution | 1 mV |
Accuracy | ± 0.5 % + 2 digits |
Conductivity measurement | |
Measurement range | 0 ... 200 µS/cm, 0.2 ... 2.0 mS/cm, 2 ... 20.0 mS/cm, 20 ... 200 mS/cm |
Resolution | 0.01 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm |
Accuracy | ±2 % of the measurement range + 1 digit |
Calibration | 1413 mS/cm |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Total dissolved solids (TDS) measurement |
|
Measurement range | 0 ... 132 ppm, 132 ... 1320 ppm, 1320 ... 13200 ppm, 13200 ... 132000 ppm |
Resolution | 0.1 ppm, 1 ppm, 10 ppm, 100 ppm |
Accuracy | ±2 % of the measurement range + 1 digit |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Salt content measurement | |
Measurement range | 0 ... 12 % (of weight) |
Resolution | 0.1 % |
Accuracy | ±0.5 % of the measurement range |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
Oxygen measurement (optional) | |
Measurement range | 0 ... 20 mg/l (in water), 0 ... 100 % (in air), 0 ... 50 ºC / 32 ºF ... 122 ºF |
Resolution | 0.1 mg/l, 0.1 %, 0.1 ºC |
Accuracy | ±0.4 mg/l, ±0.7 %, ±0.8 ºC |
Calibration | In the air |
Temperature compensation | Automatic (0 ... 50 ºC / 32 ºF ... 122 ºF) |
Temperature measurement | |
Measurement range | 0 ... 60 ºC / 32 ºF ... 140 ºF |
Resolution | 0.1 ºC |
Accuracy | ±0.8 ºC |
Temperature compensation | Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF) |
General specifications | |
Measurement rate | 1 second up to 8 hrs 59 mins 59 secs |
Display | LCD 52 x 38 mm / 2 x 1.5" |
Memory | SD card up to 16 GB (2 GB card included) |
Interface | RS-232 |
Software | Optional |
Power supply | 6 x 1.5 V AA batteries (optional power adapter) |
Operating conditions | 0 ... +50 ºC / < 85 % RH |
Dimensions | 177 x 68 x 45 mm / 7.0 x 2.7 x 1.8" |
Weight | 490 g / 1.1 lbs |
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Electrolytic solution needed for the OD OXPB-11 sensor.
ex. VAT, ex. delivery costs
Replacement sensor OXHD-04 for the OXPB-11 oxygen electrode.
ex. VAT, ex. delivery costs
The BOX-LT1 carrying case offers protection when transporting and storing measuring devices and their accessories.
ex. VAT, ex. delivery costs
Electrode for measuring the redox potential (ORP) - Range: ±2000 mV - Electrode structure is silver-silver/chloride gel - Measuring temp from 0 to 100 °C (32 to 212 °F) - Body length 150 mm
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Input voltage: 110 V AC, 60 Hz
Output voltage: DC 9 V
Output current: 0.8 A
Connector: US / North American style plug
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Input voltage: 220 / 110 V AC, 50 / 60 Hz
Output voltage: DC 9 V
Output current: 1 A
Connector: Approx. Ø 2.5 mm, UK / European style plug
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Calibration Solution pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
ex. VAT, ex. delivery costs
Calibration Solution pH7. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
ex. VAT, ex. delivery costs
Calibration Solution pH4. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
ex. VAT, ex. delivery costs
Calibration Solution pH4, pH7 and pH10. pH electrodesdriftover time,causingmeasurement errors.Toensure high accuracy, we recommendregular calibration of pH meters.
-pH 4, pH 7 and pH 10
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
pH electrode especially for wine, beer and other liquids with low conductivity
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Calibration solution 500 ml 111,8
mS / cm @ 25°C / 77°F
Potassium chloride 0.1 mol / l
DIN EN 27888
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
pH electrode especially for soil, mud and slurry
ex. VAT, ex. delivery costs
pH electrode especially for beer, blood and milk products
ex. VAT, ex. delivery costs
Calibration Solution pH4 and pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
ex. VAT, ex. delivery costs
Special pH probe: