The condition monitoring sound level meter meter consists of a measuring microphone with handle and a wall bracket with 1.5 m / 4.9 ft cable, a noise transmitter and a digital display. The main field of application of the noise measuring device is the continuous noise measurement and noise monitoring of factory buildings, production areas and major events such as night clubs, music festivals or karting tracks.

  • Range : 30 … 130dB (A)
  • Resolution: 0.1dB
  • Accuracy: ± 1.5dB
  • Alarm relay: 5A / 240VAC
  • Supply: 250V / 50Hz
  • Handle and wall mount
  • Analogue output signal
  • Incl. ISO calibration certificate
Condition Monitoring Sound Level Meter with Sound Calibrator PCE-SLT-KIT-N
US$ 800.00
ex. VAT, ex. delivery costs
The condition monitoring sound level meter consists of a measuring microphone with a handle and a wall bracket on a 1.5 m / 4.9 ft cable, a noise transmitter and a digital display. The main area of application of the condition monitoring sound level meter is the continuous noise measurement and noise monitoring of factory halls, production rooms and at major events (discos, folk festivals, kart tracks, etc.).

  • Measuring range: 30…130dB(A)
  • Resolution: 0.1 dB
  • Accuracy: ±1.5 dB
  • Alarm relay: 5A/up to 240VAC
  • Input.: 110V or 220V/50Hz or 60HZ
  • Including class II sound calibrator
Condition Monitoring Sound Level Meter PCE-SLT-TRM
US$ 458.00
ex. VAT, ex. delivery costs

The class 2 (type 2) condition monitoring sound level meter is a noise meter, sound pressure level (SPL), or decibel (dB) meter with an audible or visual alarm. Used for long-term measurement of occupational noise exposure limits, the condition monitoring sound level meter is an effective device across the industry spectrum. 


  • Class 2
  • Measuring range: 30 … 130 dB in 3 ranges
  • Resolution: 0.1 dB
  • Accuracy: ±1.5 dB
  • Frequency weighting: A
  • Time weighting: Fast
  • Output: 4 … 20 mA
  • IP 54 ingress protection rating on transmitter

Condition Monitoring Thermometer PCE-313A-ICA incl. ISO Calibration Certificate
US$ 603.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-313A condition monitoring thermometer measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313A condition monitoring thermometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the condition monitoring thermometer to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.


  • Relative humidity: 5 … 95% r.H.
  • Temperature: 0 … 50°C / 32 … 122°F
  • Type K: -50 … 1300°C / -58 … 2372°F
  • Calculated dew point: -25.3 … 48.9°C / -13.5 … 120°F
  • Wet bulb temperature: -21 … 50°C / -5.8 … 122°F
  • Memory: SD card (1 … 16 GB)
  • Incl. ISO Calibration Certificate

Paint Viscosity Tester PCE-RVI 8
US$ 2,714.00
ex. VAT, ex. delivery costs

The paint viscosity tester has a measuring range of 27…. 5250 cp and an accuracy of +1% of the measuring range. The paint viscosity tester is used, for example, in quality control of production processes. In addition, the paint viscosity tester is particularly used in laboratories of all kinds.

  • Measuring range: 27 … 5250 cp
  • Rotation speed: 200 RPM
  • Volume measuring cup: 600 ml
  • Large touch screen for easy operation
  • Temperature measuring range: -20 … 250 °C / -4 … 482 °F

Condition Monitoring Sound Level Meter PCE-SLT-TRM-ICA incl ISO calibration cert
US$ 574.00
ex. VAT, ex. delivery costs
ISO Calibration
The condition monitoring sound level meter consists of a microphone with handle, a wall bracket with 1.5 m / 4.9 ft cable, and a sound transmitter. The main application area of this sound level meter lies in continuous noise monitoring of factory sites, production lines, as well as in major events such as auto racing and festivals. 

  • Measuring range: 30 … 130 dB in three ranges
  • Resolution: 0.1 dB
  • Relay output and control output
  • Handle and wall holder
  • Analog output signal
  • Incl. ISO calibration
Condition Monitoring Class 2 Sound Level Data Logger PCE-SDL 1
US$ 296.00
ex. VAT, ex. delivery costs

PCE-SDL 1 is a condition monitoring class 2 (type 2) data-logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.


  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and Windows-compatible software for data transfer to PC

HVAC Meter PCE-IR10
US$ 567.00
ex. VAT, ex. delivery costs

The PCE-IR10 HVAC Meter is made up of a small sensor head and a separate electrical component. The HVAC Meter sensor is so small that it can fit in almost any space. part from this, the device offers similar specifications as other devices.


- Temperature range: -40 ... 600°C / -40 ... 1112°F
- Accuracy: ± 1% or ± 1°C / 1.8°F
- Optical resolution: 15:1
- Storage conditions: -40 ... 85°C / -40 ... 185°F
- Spectral range: 8.0 ... 14 µm
- Emissivity: 0.100 - 1.000 adjustable in digital mode, by units of 0.001
- Outputs: analogue, USB, RS-232, RS-485, relay

 

Condition Monitoring Sound Meter PCE-SDL 1-ICA incl. ISO-Calibration Certificate
US$ 429.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-SDL 1 is a condition monitoring class 2 (type 2) data logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The instrument is equipped with a USB interface for download the logged data to a PCE or portable.

  • Class 2
  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and PC-compatible software for data transfer