Aerosol meter PCE-PQC 20EU Incl. Calibration Certificate
US$ 7,861.00
ex. VAT, ex. delivery costs
ISO Calibration
The Aerosol meter PCE-PQC 20EU is very well suited for monitoring and checking of clean rooms, filter systems in operating rooms and filling systems in the pharmaceutical industry. The stored data records from the Aerosol meter can be read out and processed via the supplied software via Ethernet, USB or Wifi. 

  • Measuring range: 0.3 … 25 μm
  • Measurement channel sizes: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
  • Counting efficiency: 50% at 0.3 μm, 100% at > 0.45 μm according to JIS
  • Ethernet, USB
  • Incl. temperature and humidity sensor
  • Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921
Aerosol particle counter PCE-PQC 20EU Incl. Calibration Certificate
US$ 7,861.00
ex. VAT, ex. delivery costs
ISO Calibration
The Aerosol particle counter PCE-PQC 20EU is very well suited for monitoring and checking of clean rooms, filter systems in operating rooms and filling systems in the pharmaceutical industry. The stored data records from the Aerosol particle counter can be read out and processed via the supplied software via Ethernet, USB or Wifi. 

  • Measuring range: 0.3 … 25 μm
  • Measurement channel sizes: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
  • Counting efficiency: 50% at 0.3 μm, 100% at > 0.45 μm according to JIS
  • Ethernet, USB
  • Incl. temperature and humidity sensor
  • Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921
Material Hardness Tester PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

Material Hardness Tester PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

Metal Hardness Tester PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

NDT Test Instruments PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

UCI Durometer PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable hardness tester or durometer that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys to measure on a minimum material thickness of 2 mm / .08 in. The test instrument can be mounted on a test stand (as an option) for series measurement in manufacturing process checking. Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

UCI Hardness Tester PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data
  • Different probe types (also automatic motorized probes) available

Ultrasonic / UCI Hardness Tester PCE-5000
US$ 7,797.00
ex. VAT, ex. delivery costs

PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.

  • Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
  • Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
  • Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
  • Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
  • Memory size: 1,000 groups for measurement data and 20 groups for calibration data