3-Phase Power Meter Easycount-3-16-A
US$ 363.00
ex. VAT, ex. delivery costs

The mobile 3-phase power meter Easycount-3-16-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile 3-phase power meter are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54

Power Analyzer Easycount-3-16-A
US$ 363.00
ex. VAT, ex. delivery costs

The mobile power analyzer Easycount-3-16-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile power analyzer are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54

Power Meter Easycount-3-16-A
US$ 363.00
ex. VAT, ex. delivery costs

The mobile power meter Easycount-3-16-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile power meter are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54

Electrical Tester Easycount-3-16-A
US$ 363.00
ex. VAT, ex. delivery costs

The mobile electrical tester Easycount-3-16-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile electrical tester are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54

3-Phase Power Meter Easycount-3-32-A
US$ 389.00
ex. VAT, ex. delivery costs

The mobile 3-phase power meter Easycount-3-32-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile 3-phase power meter are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54
  • Counter calibrated

Power Analyzer Easycount-3-32-A
US$ 389.00
ex. VAT, ex. delivery costs

The mobile power analyzer Easycount-3-32-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile power analyzer are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54
  • Counter calibrated

Power Meter Easycount-3-32-A
US$ 389.00
ex. VAT, ex. delivery costs

The mobile power meter Easycount-3-32-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile power meter are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54
  • Counter calibrated

Electrical Tester Easycount-3-32-A
US$ 389.00
ex. VAT, ex. delivery costs

The mobile electrical tester Easycount-3-32-A is an energy meter, installed in a splash-proof and impact-resistant housing, for three-phase current up to 400 V. The approx. 50 cm / 19.6" long cable ends of the mobile electrical tester are equipped with a CEE plug and a CEE coupling.

  • Display: 6+1 roller counter
  • Resolution: 0.1 kWh
  • Degree of protection meter: IP 54
  • Counter calibrated

Three-Phase Power Meter PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The Three-Phase Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three-Phase Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. 


  • PCE-830 + PCE-3007 flexible amp clamp (3000 A)
  • Electrical conductor pick-up: 170 mm / 6.69 in diameter
  • Length of electrical conductor: 610 mm / 24.0 in
  • Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values - single phase)

Three-Phase Power Analyzer PCE-830-3-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830-3 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


  • PCE-830 + PCE-3007 flexible amp clamp (3000A)
  • Electrical conductor pick-up: 170 mm / 6.7 in diameter
  • Minimum radial curve: 35 mm / 1.4 in
  • Length of electrical conductor: 610 mm / 24 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB / max. 52,420 data (1 phase)
  • Incl. ISO calibration certificate

Carbon Monoxide Meter Xgard Type 1 CO
US$ 1,083.59
ex. VAT, ex. delivery costs

The Xgard-1-CO is a single-gas Carbon Monoxide Meter used to warn for gases (Carbon Monoxide, CO, 0 … 250 ppm), with display and signal output for sensors in combination with a stationary instrument to detect gases (ATEX or UL approval).


  • Stationary
  • For (Carbon Monoxide, CO, 0 … 250 ppm)
  • Additional display and alarm station
  • ATEX or UL approval

Gas Leak Detector Xgard Type 1 CO
US$ 1,083.59
ex. VAT, ex. delivery costs

The Xgard-1-CO is a single-gas Gas Leak Detector used to warn for gases (Carbon Monoxide, CO, 0 … 250 ppm), with display and signal output for sensors in combination with a stationary instrument to detect gases (ATEX or UL approval).


  • Stationary
  • For (Carbon Monoxide, CO, 0 … 250 ppm)
  • Additional display and alarm station
  • ATEX or UL approval

Gas Detector Xgard Type 1 CO
US$ 1,083.59
ex. VAT, ex. delivery costs

The Xgard-1-CO is a single-gas gas detector used to warn for gases (Carbon Monoxide, CO, 0 … 250 ppm), with display and signal output for sensors in combination with a stationary instrument to detect gases (ATEX or UL approval).


  • Stationary
  • For (Carbon Monoxide, CO, 0 … 250 ppm)
  • Additional display and alarm station
  • ATEX or UL approval

CO2 Analyser Gas-Pro-3
US$ 2,525.03
ex. VAT, ex. delivery costs

This CO2 Analyser Gas-Pro-3 can gauge with its sensors a maximum of five different gases. Because of this versatility, the CO2 Analyser Gas-Pro-3 is ideal for use in a variety of applications, such as: near canals, sewage treatment plants, drains, wastewater facilities, dumps/landfills, chemical/oil plants, shipping ports and more.


  • Purpose: Personal protection
  • Sensor type: CO / CO2 / H2S / O2 / CH4
  • Memory: Yes
  • Interface: USB
  • Includes suction pump
  • Other gas sensors available upon request. Please email jmu@pce-  instruments.com (UK) or rhe@pce-instruments.com (US) for details


Clamp on Tester PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830-3 Clamp on Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp on Tester also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-3007 flexible amp clamp (3000 A)
  • Electrical conductor pick-up: 170 mm / 6.69 in diameter
  • Length of electrical conductor: 610 mm / 24.0 in
  • Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values - single phase)

Clamp Meter PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830-3 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-3007 flexible amp clamp (3000 A)
  • Electrical conductor pick-up: 170 mm / 6.69 in diameter
  • Length of electrical conductor: 610 mm / 24.0 in
  • Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values - single phase)

Power Analyzer PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830-3 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-3007 flexible amp clamp (3000 A)
  • Electrical conductor pick-up: 170 mm / 6.69 in diameter
  • Length of electrical conductor: 610 mm / 24.0 in
  • Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values - single phase)

Power Meter PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830-3 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


  • PCE-830 + PCE-3007 flexible amp clamp (3000 A)
  • Electrical conductor pick-up: 170 mm / 6.69 in diameter
  • Length of electrical conductor: 610 mm / 24.0 in
  • Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
  • Sampling rate: 2 sec.
  • Memory size: 512 kB (max. 52,000 values - single phase)