A tension dynamometer is based on the principle that the force acting on the pressure adapter is measured hydraulically. The hydraulic pressure generated is displayed by the tension dynamometer on a scale in Newtons.
- Measuring range: 0… 10,000 N / 2,248 lbs
- Resolution: 200 N / 45 lbs
- Measuring accuracy: ±1.95% f. R.
- Incl. ISO calibration certificate
- with 100 cm hydraulic hose
- External analogue display
A tension dynamometer is based on the principle that the force acting on the pressure adapter is measured hydraulically. The hydraulic pressure generated is displayed by the tension dynamometer on a scale in Newtons.
- Measuring range: 0… 2,500 N / 562 lbs
- Resolution: 100 N / 22.5 lbs
- Measuring accuracy: ±1.95% f. R.
- with 100 cm hydraulic hose
- External analogue display
- Incl. ISO calibration certificate
A tension dynamometer is based on the principle that the force acting on the pressure adapter is measured hydraulically. The hydraulic pressure generated is displayed by the tension dynamometer on a scale in Newtons.
- Measuring range: 0… 1,000 N / 225 lbs
- Resolution: 20 N / 4.5 lbs
- Measuring accuracy: ±2.5% of the measuring range
- with 100 cm hydraulic hose
- External analogue display
- Incl. ISO calibration certificate
Air flow meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of air flow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Data logger to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of airflow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Air velocity meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of air velocity meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
An environmental meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of environmental meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
An environmental tester to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of environmental tester is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Thermo-Anemometer to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of Thermo-Anemometer is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Wind speed meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of wind speed meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
The PCE-VT 204 is a multifunction handheld accelerometer device with the ability to accurately measure both rotation and vibration. An ideal tool for the testing and inspection of machine parts and components such as motors, transmissions, gears, gear boxes and wheels, this multi-purpose instrument measures revolutions per minute (RPMs) as well as three-axis vibration, i.e., speed or velocity, displacement and acceleration.
- Vibration measurement: Velocity or speed, acceleration and displacement
- RPM measurement: Contact / mechanical and noncontact / optical
- Internal memory for up to 1000 readings
- Min / max and data hold functions
- RS-232 port