Flow Meter PCE-PDA 10L
US$ 930.00
ex. VAT, ex. delivery costs

The Flow Meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The Flow Meter PCE-PDA 10L has many different pressure measuring functions.


  • Measuring range: ± 20 kPa /± 2.9 psi / ± 0.2 bar
  • Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
  • Accuracy: ± 0.5% of final value
  • Min and Max value memory
  • Data logger and leak test
  • Temperature measurement, flow measurement
  • Pitot tube not included in delivery / optionally selectable

Flow Meter PCE-A420-ICA incl. ISO Calibration Certificate
US$ 923.00
ex. VAT, ex. delivery costs
ISO Calibration

Without a doubt, the main advantage of this handheld cup vane flow meter is that it doesn't need to be held exactly in the direction of the wind. Flow meter with impellers typically have to be held exactly in the direction of the flow to take accurate measurements. Digital cup vane flow meter, wind direction will not influence the measurement.


  • 0.9 to 35.0 m/s
  • 2.5 to 126.0 km/h
  • 1.4 to 68.0 knots
  • 1.6 to 78.2 miles/h 
  • incl. ISO Calibration Certificate

Air Flow Meter PCE-009
US$ 913.00
ex. VAT, ex. delivery costs

This air flow meter has a good relation between price and quality and it combines accuracy and versatility with the ability to transfer data directly to a computer. This air flow meter forms a part of a professional's basic equipment to regulate and test ventilation systems. All the test instruments come manufacturer calibrated. ISO certification can be made as an option.


- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0°C / 32 ... 122°F (sensor)
- Volume of air current:  0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Sampling rate: 1 sec

Air Flow Meter PCE-PDA 10L
US$ 930.00
ex. VAT, ex. delivery costs

The air flow meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The air flow meter PCE-PDA 10L has many different pressure measuring functions.


  • Measuring range: ± 20 kPa /± 2.9 psi / ± 0.2 bar
  • Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
  • Accuracy: ± 0.5% of final value
  • Min and Max value memory
  • Data logger and leak test
  • Temperature measurement, flow measurement
  • Pitot tube not included in delivery / optionally selectable

PCE-TDS 200 L SENSOR for the Ultrasonic Flow Meter
US$ 959.00
ex. VAT, ex. delivery costs
Large sensor pair for pipe diameters DN 300 … 6000 mm. This sensor pair is therefore suitable for particularly large pipes. The sensors for the ultrasonic flow meter can be attached with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with ferrous metal. The sensors have a dimension of 91 x 52 x 44 mm.

  • Pipe diameter: DN 300 … 6000 mm / 11.8 x 236"
  • Dimension: 91 x 52 x 44 mm / 3.5 x 2.0 x 1.7"
  • Important! If you order the sensor later, we need the PCE-TDS 200 handheld unit,   to adjust the sensor to the handheld unit!
PCE-TDS 200 SR SENSOR On Rail sensors for the Ultrasonic Flow Meter
US$ 838.00
ex. VAT, ex. delivery costs
Connected on-rail sensors for pipe sizes DN 15 … 100 / 20 … 108 mm. Both sensors are located on one rail to simplify the positioning of the sensors. For easier handling, there is a corresponding handle on the rail.

Magnets are located underneath the rails to enable it to hold on to pipes with a ferrous metal by itself.

  • Pipe sizes: DN 15 … 100 / 20 … 108 mm / 0.6 … 3.9 / 0.7 … 4.2"
  • Important! If you order the sensor at a later date, we require the PCE-TDS 200 hand-held unit,   in order to match the sensor to the hand-held unit!
Air Flow Meter PCE-A420-ICA incl. ISO Calibration Certificate
US$ 923.00
ex. VAT, ex. delivery costs
ISO Calibration

Without a doubt, the main advantage of this handheld cup vane air flow meter is that it doesn't need to be held exactly in the direction of the wind. Air flow meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air flow meter, wind direction will not influence the measurement.


  • 0.9 to 35.0 m/s
  • 2.5 to 126.0 km/h
  • 1.4 to 68.0 knots
  • 1.6 to 78.2 miles/h
  • incl. ISO Calibration Certificate

NDT Test Instruments PCE-DDA 10 Shore A
US$ 839.00
ex. VAT, ex. delivery costs

The PCE-DDA 10 shore hardness tester is an ergonomic device to check Shore hardness in gum, plastic and other non-metallic materials. It has been designed with a very high quality. The PCE-DDA 10 durometer is mainly used for soft gums, elastomers, natural rubber, neoprenes, casting resin, white PVC, leather, etc. It has a reading accuracy of 0.1 hardness units. The durometer (as all test instruments) comes manufacturer calibrated and can additionally be lab certified to ISO standards.


  • Handheld device
  • For Shore A measurements
  • Single and Serial Measurements
  • Data transfer to PC

Data-Logging Noise Meter / Sound Meter PCE-NDL 10
US$ 977.00
ex. VAT, ex. delivery costs

The data-logging noise meter / sound meter  is used to determine volume. The PCE-NDL 10 data-logging noise meter / sound meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the data-logging noise meter / sound meter has an SD card slot that enables the use of an SD card as an additional storage medium.


  • Measuring range: SPL: Auto 30 … 130 dB
  • Resolution: 0.1 dB
  • Low sampling rate
  • Automatic or manual storage
  • Selectable storage interval
  • Backlit LC display
  • Dose measurement or SPL measurement