The electrical tester is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the electrical tester.
The insulation tester is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the insulation tester.
The isolation meter is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the isolation meter.
The PAT tester is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the PAT tester.
The photovoltaic meter is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the photovoltaic meter.
The Photovoltaic Tester is for insulation measurements with a test voltage of up to 15 kV. The measuring range of 0 … 30 TΩ and other measuring functions make the tester versatile. With 4 quick selection buttons for common test voltages and the option of setting the voltage in 500 V steps. Pre-configured diagnostic tests, including (PI), dielectric absorption ratio (DAR) and a memory function for 200 measurements are integrated into the photovoltaic meter.
The ultrasonic wall thickness gauges can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the ultrasonic wall thickness gauges.
Measuring range: 1.20 … 300.0 mm / 0.04 … 11.81"
Accuracy: ±0.5% of measured value + 0.05 mm
Memory capacity: 1500 measured values
Calibration reference on housing
High temperature probe: -10 … 350 °C / 14 … 662 °F
The thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the thickness meter.
Measuring range: 1.20 … 300.0 mm / 0.04 … 11.81"
Accuracy: ±0.5% of measured value + 0.05 mm
Memory capacity: 1500 measured values
Calibration reference on housing
High temperature probe: -10 … 350 °C / 14 … 662 °F
The Ultrasonic testing device can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the Ultrasonic testing device.
Measuring range: 1.20 … 300.0 mm / 0.04 … 11.81"
Accuracy: ±0.5% of measured value + 0.05 mm
Memory capacity: 1500 measured values
Calibration reference on housing
High temperature probe: -10 … 350 °C / 14 … 662 °F