The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-779N-ICA thermometer measures temperatures quickly and without contact. The thermometer can be used for almost all surfaces. The emissivity of the thermometer is adjustable over the range of 0.1 ... 1.0. The thermometer has various measurement functions such as max, min and average measurement.
- OLED-Display
- Measuring range: -60 ... 760°C / -76 ... 1400°F
- Additional thermocouple measurement -64 ... 1400°C / -83.2 ... 2552°F
- Dual Laser
- Resolution: 0.1°C / 0.18°F at -83.2 ... 999.9°C (-117.8 ... 1831.8°F), otherwise 1°C / 1.8°F
- incl. ISO Calibration Certificate
The 4-channel PCE-VM 5000-ICA Accelerometer performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000-ICA Vibration Meter performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The Multifunction Thermometer PCE-THA 10 is easy to operate with one hand thanks to its compact size, the new structure and integrated impeller. In addition to the temperature, the thermometer measures the wind speed, humidity, dew point, the wet bulb temperature and the air volume. Average wind speed values can be determined with the thermometer from the 20 preset points.
- Temperature measuring range: -15 ... 50°C / 5 ... 122°F
- Humidity range: 5 ... 95% RH
- Air speed: 0.4 ... 35 m / s
- Air flow: 0 ... 9.999 m3 / s
- Incl. ISO Calibration Certificate
The 4-channel PCE-VM 5000-ICA Vibration Analyzer performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The Electrical Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Electrical Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-779N-ICA Digital Thermometer measures temperatures quickly and without contact. The digital thermometer can be used for almost all surfaces. The emissivity of the digital thermometer is adjustable over the range of 0.1 ... 1.0. The digital thermometer has various measurement functions such as max, min and average measurement.
- OLED-Display
- Measuring range: -60 ... 760°C / -76 ... 1400°F
- Additional thermocouple measurement -64 ... 1400°C / -83.2 ... 2552°F
- Dual Laser
- Resolution: 0.1°C / 0.18°F at -83.2 ... 999.9°C (-117.8 ... 1831.8°F), otherwise 1°C / 1.8°F
- incl. ISO Calibration Certificate
The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate