The PCE-HT 71N Temperature Meter detects air temperature and humidity and stores readings in its internal memory. The Temperature Meter has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a Temperature Meter in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 70°C / -31 ... 158°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The PCE-T390 temperature meter is a digital device with four input channels for type K and type J temperature sensors and two input channels for PT100 temperature sensors. The PCE-T390 temperature meter has a SD card slot (from 1 ... 16 GB) for storing the measured data. The data is stored in xls format on the SD card of the temperature meter so that no additional software is needed for further analysis.
- 4 input channels for type-K, J temperature sensors
- 2 input channels for Pt100 temperature sensors
- 2 x type-K TF-500 temperature sensors are included in the package
- SD card memory (1 ... 16 GB)
In loud environments, it is often difficult to pinpoint the source of a sound. The easy-to-operate PCE-MSV 10 noise meter visualizes sound in real time, creating a visible roadmap to a sound’s source. Also referred to as a sound meter, sound pressure meter, portable sound camera or sound level camera, the PCE-MSV 10 noise meter can be used in various stages of machine and equipment design, manufacture and operation, from engineering research and development (R&D) to preventative maintenance and beyond. Lightweight and compact, the PCE-MSV 10 portable sound camera features:
- Measurement range of 30 … 130 dBA
- Frequency range of 160 … 6000 Hz
- Real-time image and video recording
Moisture meter for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture meter for liquid materials has a processing unit with RS232/RS485 interfaces.
- Measurement range: 0 ... 100 %
- Limits of permissible absolute error of the measurements: Δ= 0,035 +0,05·W
- Temperature measurement range: -40 ... +150 °C
The PCE-313A temperature meter measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313A temperature meter can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the temperature meter to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
- Incl. ISO Calibration Certificate
The data logger for temperature and humidity precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The data logger for temperature and humidity is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
Suitable for determining the humidity of bulk substances, this moisture test instrument can be fitted into containers and systems such as troughs,
bunkers, distributors, augers, conveyors, bins and silos. This permits
24/7 moisture measurement of fibrous materials, sawdust, gravel, fly ash
(mineral), wood chips (surface to 5 cm) feed grain, flour, pastes,
seed, or similar bulk or flowing substances. These test instruments / test sensors are mainly for use in manufacturing processes to give the opportunity of process optimization to the manufacturer or to insure the moisture content of the final product.
- PCE-MWM 240-B Rod sensor (custom length 500 ... 1500 mm)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C (+41 ... +176 °F)
- Analog and digital signal output