The Temperature Data Logger with logging function is a versatile tool in that it can measure the temperature of objects without contact and readings can be stored in memory and transferred to a computer by way of its RS-232 interface and software. This Temperature Data Logger comes complete, allowing the user to program specific time intervals for taking measurements, such as over an entire week. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Temperature range: -40 to 500°C / -40 ... 932°F
- Resolution: 0.1°C / 0.18°F
- Accuracy: ±2% of reading or ±2°C / 3.6°F
- Optical resolution: 8:1
- Emissivity: 0.3 to 1.0 (adjustable)
- Interface: RS-232
- Display: LCD
Infrared thermometer for temperatures up to + 500 °C. The measured data can be stored and snet to a computer later on, but the main significant feature of this infrared thermometer is the built-in printer. This makes the test instrument very attractive for use in food applications. As all test equipment, this infrared thermometer is delivered manufacturer calibrated and can additionally be certified to ISO.
- Temperature range: -40 to 500 °C / -40 ... 932 °F
- Resolution: 0.1 °C / 0.18 °F
- Accuracy: ±2 % of reading or ±2 °C / 3.6 °F
- Optical resolution: 8:1
- Emissivity: 0.3 to 1.0 (adjustable)
- Interface: RS-232
- Display: LCD
PCE-VE 370HR3 is a four-way articulating industrial borescope / inspection camera for the non-destructive inspection (NDI) of hard-to-reach places. The waterproof borescope camera head features 5 LED lights (3 front, 2 side) for optimal illumination. In addition, digital image magnification or zoom of up to 2 times is available, plus boost functionality for improved image quality in the dark.
- With boost function: better images in dark surroundings
- 2 additional side LEDs for better lighting
- Diameter: Ø 6 mm / 0.24"
- 4-way camera
- Memory: 8 GB SD memory card (incl.)
- Cable length: 3 m / 9ft 10"
The Air and Temperature Meter PCE-VA 11 is an extensively used measuring instrument. This temperature meter offers the opportunity to determine air speeds, air temperature and infrared temperature. The illuminated LCD allows comfortable readings and facilitates use in dimly lit areas.
- Air speed range: 0.4 ... 30 m/s / 0.9 ... 67 mph
- Air flow range: 0 ... 9999 CFM / CMM
- Air temperature range: -10 ... 60°C / 14 ... 140°F
- IR temperature range: -50 ... 500°C / -58 ... 932°F
Infrared Thermometer with LCD for continuous measurement of surface temperature of all solid materials, designed for fixed installation.
- Temperature range: -40 ... 600 °C / -40 ... 1112 °F
- Accuracy: ± 1% or ± 1°C / 1.8°F
- Optical resolution: 15:1
- Storage conditions: -40 ... 85°C / -40 ... 185°F
- Spectral range: 8.0 ... 14 µm
- Emissivity: 0.100 - 1.000 adjustable in digital mode, by units of 0.001
- Outputs: analogue, USB, RS-232, RS-485, relay
The Class 1 outdoor decibel meter PCE-432-EKIT can be used, e.g, for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor decibel meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The moisture meter is a sensor for measuring moisture of sand consisting of a central probe surrounded by four other probes. The probes and sensor housing are made of stainless steel AISI 321. Our moisture meter is ideally suited for installation in tanks with liquid materials such as fuel oil, sludge from cement production, fuels (CWF).
- Readability mass fraction of water: 0 ... 100%
- Moisture measurement range: ± 0.1 ... 100% (water mass fraction)
- Maximum permissible absolute error moisture measurement: Varies by material, lab test required
- Temperature range: +5 ... +80 °C
The Class 1 outdoor SPL meter PCE-432-EKIT can be used, e.g, for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor SPL meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
This temperature meter station with outside sensor is a real all-rounder. The wireless temperature meter station with outside sensor is easy to assemble based on the instructions provided. You do not have to be a professional to operate the wireless temperature meter station and outside sensors. The weather data of the temperature meter station with outside sensor for different parameters are sent up to 100 meters by radio signal to the main station.
- 3 displays
- Indoor temperature in Celsius or Fahrenheit
- Outside temperature in Celsius or Fahrenheit
- Indoor air humidity / outdoor air humidity
- Air pressure gauge in inHg or hPa
- Absolute or relative air pressure display selectable
- Precipitation indication in mm or inch
- Precipitation indicator for 1 hour, 24 hours, 1 week, 1 month
- Wind speed in mph, km/h, m/s, knots ...
- Wind direction indicator
- Wind chill temperature gauge
- Weather forecast, trend indicator, storm warning
- and much more...
The temperature data logger is used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data recording device is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
The PCE-VM 40C Vibration Meter with SMS alert functionality was designed for vibration and shock metering on buildings, bridges, towers, and other artificial structures. The Vibration Meter measures vibrations in accordance to DIN 4150-3, BS 7385 and SN 640312A standards. With its internal memory for up to 100,000 readings, the PCE-VM 40C Vibration Meter can determine the effects of construction sites, traffic, or industrial processing on buildings over a long period of time. Features a micro SD card, GSM modem (optional), warning and alarm leds, relay output, SMS alerts (optional), and an internal battery.
- Designed for building / construction vibration monitoring
- Triaxial acceleration meter
- In accordance with BS 7385 standard
- SMS alarm notifications (optional)
- FFT analysis, XYZ and vector sum display
- Quad band GSM
- SMS alarm notifications
The PCE-CSM 7 is a portable Whiteness Meter used to measure different spectral parameters. This user-friendly, ergonomically designed Whiteness Meter automatically performs a white and black calibration when powered on. Suitable for manufacturing quality control as well as product research and development, the Whiteness Meter offers impressive measuring accuracy and comes manufacturer calibrated. Camera/illumination locating for small samples.
- Color spaces: CIEL*a*b*C*h* CIEL*a*b* CIEXYZ CIERGB CIEL*u*v*
CIEL*C*h +Yellowness + Whiteness + Color Fastness
- Offers two different measuring apertures, 4 and 8 mm
- Three light sources D65, D50, A
- Optional liquid sample kit listed under accessories
- Storage of 100 reference values and 20,000 samples
- Illumination/Viewing Angles 8°/d