PCE-IR 1800 is a high-temperature infrared (IR) temperature gun, thermometer or pyrometer ideal for use in steel, metal and ceramic mold casting and other high-temperature industrial applications. The pyrometer's internal memory stores up to 2000 measurement protocols. The device includes a USB port, data cable and Windows-compatible software for quick and easy data transfer to a PC.
- Measurement range: 650 ... 1800°C / 1202 ... 3272°F
- Accuracy: ±0.3% ± 2°C / 3.6°F at 23 ± 5°C / 9°F
- Optical resolution: 300:1
- Spectral range: 1.0 µm
- Adjustable emissivity: 0.100 ... 1.000
PCE-COM 20 is a portable handheld non-destructive conductivity tester for non-ferrous metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Includes 3 standards for testing.
- Operating frequency: 60 kHz
- Sine wave probe: Ø 14 mm / ≈ 0.55 in
- Memory: Up to 500 groups of measurements
- Lift-off and temperature compensation
- Automatic calibration
The 2-point process controller / temperature controller is a compact PID controller for a wide range of tasks. As an input signal, this 2-point temperature controller PCE-RE22 processes resistance sensors and thermocouples. Different operating modes can be selected for optimum control of the control variable. Starting with a simple on / off control with adjustable hysteresis up to the PID control, the 2-point temperature controller offers a wide range of possibilities.
- Signal input: temperature signals (PT100, PT1000, J, T, K, S, R, B, E, N, L)
- Possible control characteristics: P, PD, PI, PID, On / Off control
- Front is protected to IP 65
- 4 LEDs for status display
The PCE-A-315 inline or in-process moisture sensor provides exceptionally accurate grain moisture measurement in real time. The PCE-A-315 in-process moisture meter uses low-power microwaves to penetrate the surface every 0.2 second and obtain interior moisture readings without causing any damage. An integrated temperature probe ensures the readings are accurate from 5°C to 55°C / 41°F to 131°F. Suitable for the continuous monitoring of moisture in corn, soybeans, wheat, rice, sorghum, barley, oats, rye, hops, green coffee, cocoa beans, oil seeds, flax seeds, sunflower seeds, poppy seeds, pumpkin seeds, spelt seeds, buckwheat, sesame, peas, fava beans, scarlet runner beans, triticale, amaranth and jatropha.
- Boasts a measurement range of 5% to 40% for moisture content during
continuous mass flow with an error of just ±0.5% from 5% to 18% grain
moisture
- Lowers energy costs by enabling shorter drying times and reduces labor costs
by automating the moisture monitoring process
- Provides nearly maintenance-free operation, delivering consistently accurate
moisture readings over time
- Analog output of 4 to 20 mA can be converted to digital for dryer control
PCE-WM1 is a multi-function temperature meter used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³
For industrial continuous production of wood pellets, chips, sawdust and similar materials when in-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 210 moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: +5 ... +80 °C (+41 ... +176 °F)
- Questionnaire starts evaluation process
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
The digital temperature indicator is equipped with a 55-digit bar graph display, which is freely programmable. In addition, the digital indicator also comes with a conventional display, which shows the active measuring value as a figure. The digital universal indicator is able to process a large variety of signals.
- 55-digit bar graph display
- 4-digit, 7-segment display
- Analogue output
- Four alarm relays
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
The PCE-HT110 Temperature Meter or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110 is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
For industrial continuous production of wood pellets, chips, sawdust and similar materials when on-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 300P moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: -40 ... +150 °C (-40 ... +302 °F)
- Current consumption: 200 mA
- Power supply : 24 (18 ... 36) VDC
- Questionnaire starts evaluation process
- Application: pellets, wood chips
PCE-T 1200 is a 12-channel datalogging temperature meter that accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel