A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.
- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate
The PCE-TG 300-NO5/90 is a paint thickness tester for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the paint thickness tester. Wall thicknesses under a coating can also be measured with the paint thickness tester.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
With this Paint Thickness Gauge, layer thicknesses on metallic surfaces can be reliably determined. The Paint Thickness Gauge has a measuring range of 1500 µm. This means that the Paint Thickness Gauge is used, for example, in a paint shop, for incoming goods inspection or for an expert.
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
The PCE-TG 300-NO5/90 is a paint thickness tester for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the paint thickness tester. Wall thicknesses under a coating can also be measured with the paint thickness tester.
- Measuring range: 1 ... 600 mm / 0.039 ... 23.62" (steel)
- Diameter: 10mm / 0.39"
- Sensor at 90° angle
- Minimum diameter of pipes: 20 x 3 mm / 0.787 ... 0.118"
- Frequency: 5 MHz
- Bluetooth
- incl. ISO calibration certificate
This paint testing song is especially designed for meat, food, vegetables or wet products testing. Only the aperture comes into contact with the surfaces to be measured. So it is guaranteed that no liquids can cause cross contamination while doing the measurement. The paint testing equipment simulates to see surfaces like with human eyes. Used mainly in the medical and food industry the color test instrument in addition meets all requirements for plastics surface measurements (PP, PE, PET, ABS, EVA) and also powders. The paint testing equipment is delivered manufacturer calibrated, but can optionally be certified to ISO standards.
- Measuring aperture of 20 mm and 45°/0° illumination/viewing angle
- Rechargeable lithium-ion battery
- Auto white black calibration
- Designed specifically for the food industry
- Software included