The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The data-logging sound level meter is used to determine volume. The PCE-NDL 10 data-logging sound level meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the data-logging sound level meter has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement
PCE-SDL 1 is a class 2 (type 2) data logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The instrument is equipped with a USB interface for download the logged data to a PCE or portable.
- Class 2
- Measuring range: 30 ... 130 dB
- Accuracy: ± 1.4 dB
- Frequency: 31.5 Hz ... 8 kHz
- Frequency weighting: A and C
- Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
- Includes USB interface and PC-compatible software for data transfer
- incl. ISO Calibration Certificate
A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.
- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate
The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials.
The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore.
The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate
The Class 1 outdoor decibel meter PCE-432-EKIT can be used, e.g, for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor decibel meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The noise meter / sound meter PCE-MSM 4 has features that you will only find in other more expensive devices. The class 2 noise meter / sound meter in a slim design is ideal for mobile measurements of sound. It is not easy to find an instrument of this level for such a low price.
- Class 2
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Frequency range: 31.5 Hz ... 8 kHz
- Time weighting: Fast, Slow
- Frequency weighting: A, C
- incl. ISO-Calibration Certificate
The Class 1 outdoor SPL meter PCE-432-EKIT can be used, e.g, for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor SPL meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
PCE-322A-ICA is a handheld, portable, professional Class II noise meter, sound meter or decibel (dB) meter with built-in data-logging or data-recording functionality. Thus, PCE-322A-ICA is ideal for real-time noise measurement as well as for long-term noise exposure monitoring over time.
- Sound measuring range: 30 ...130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory: Stores up to 32,700 readings
- Sampling rate: 2 times per second
- ISO calibration available as an option
- Incl. calibration certificate
The data-logging noise meter / sound meter is used to determine volume. The PCE-NDL 10 data-logging noise meter / sound meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the data-logging noise meter / sound meter has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement