The class 2 outdoor sound level data logger PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc.
The outdoor sound level data logger is equipped with an octave band frequency filter.
Optionally, the outdoor sound level data logger can be upgraded with a 1/3 octave band filter.
The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level data logger over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The data-logging decibel meter is used to determine volume. The PCE-NDL 10 data-logging decibel meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the data-logging decibel meter has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement
The data logger with USB interface PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is a class 2 device and is equipped with an octave band frequency filter. Optionally, the data logger with USB interface PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
PCE-SDL 1 is a class 2 (type 2) data logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The instrument is equipped with a USB interface for downloading the logged data to a PCE, laptop or tablet.
- Class 2
- Measuring range: 30 ... 130 dB
- Accuracy: ± 1.4 dB
- Frequency: 31.5 Hz ... 8 kHz
- Frequency weighting: A and C
- Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
- Includes USB interface and PC-compatible software for data transfer
The Sound Level Data Logger PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.
The environmental meter PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The environmental meter is a class 2 device and is equipped with an octave band frequency filter. Optionally, the environmental meter PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
PCE-SDL 1 is a class 2 (type 2) data-logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.
- Measuring range: 30 ... 130 dB
- Accuracy: ± 1.4 dB
- Frequency: 31.5 Hz ... 8 kHz
- Frequency weighting: A and C
- Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
- Includes USB interface and Windows-compatible software for data transfer to PC
PCE-SDL 1 is a class 2 (type 2) data-logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.
- Measuring range: 30 ... 130 dB
- Accuracy: ± 1.4 dB
- Frequency: 31.5 Hz ... 8 kHz
- Frequency weighting: A and C
- Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
- Includes USB interface and Windows-compatible software for data transfer to PC
The PCE-830 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The data-logging decibel meter is used to determine volume. The PCE-NDL 10 data-logging decibel meter is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the data-logging decibel meter has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.