Multifunction Moisture Analyzer PCE-MA 110-ICA Incl. ISO Calibration Certificate
US$ 1,373.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-MA 110 is a halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.


- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate

Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
- Sensor for pipe diameters DN 50 ... 700 / 57 ... 720 mm, DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO-Calibration Certificate
Absolute Moisture Sensor PCE-MWM 230
US$ 5,214.00
ex. VAT, ex. delivery costs

VHF-Band Moisture sensor Crushed soil, sand, stone, Gravel, Ore. The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 250 °C. The moisture sensor probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture sensor can also be used for soil moisture control.


- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
  0 ... +90 °C (industrial version)
  0 ... +115 °C (extended temperature range)
  0 ... +250 °C (drying kilns)

 

Portable Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Data Logging Instrument PCE-830-3-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate

Outdoor Construction Noise Meter Kit PCE-432-EKIT-ICA incl ISO Calibration Cert.
US$ 6,917.00
ex. VAT, ex. delivery costs
ISO Calibration

The Class 1 outdoor construction noise meter kit PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor construction noise meter kit is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.

 

- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
Incl. ISO calibration certificate

Portable Ultrasonic Flow Meter PCE-TDS 200+ S-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- Sensor for pipe diameter DN 15 ... 100 / 20 ... 108 mm
- Sensor dimensions: 91 x 52 x 44 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Gloss Meter PCE-IGM 100-ICA incl. ISO calibration certificate
US$ 3,361.00
ex. VAT, ex. delivery costs
ISO Calibration

A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.


- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate

Absolute Moisture Sensor PCE-MWM 240-A
US$ 6,588.00
ex. VAT, ex. delivery costs

Designed specifically for use in humidity measurement of bulk materials, this moisture sensor is installed in bins, silos, troughs, bunkers case, distributors, augers and conveyors. Material in bulk or flowing mass, such as fibrous materials, gravel, sawdust, fly ash (mineral), wood chips (surface to 5 cm) feed grain, flour, seed, pastes, ... is continuously measurable.

- Stainless sensor rod (250 mm length)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C  (+41 ... +176 °F)
- Analog and digital signal output

HVAC Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The HVAC thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the HVAC thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Moisture Meter PCE-THB 40-ICA incl. ISO Calibration Certificate
US$ 567.00
ex. VAT, ex. delivery costs
ISO Calibration
The Moisture Meter records the air temperature as well as the relative humidity and the barometric pressure and saves them internally on an SD card. The compact device with a large memory (up to max. 16 GB SDHC card) is primarily used for long-term registration in the food sector (refrigerated counters in department stores, refrigerated transports, warehouses) as well as for measurement and recording in industry (heating and cooling processes, machine temperatures, product storage, etc.).

Measuring ranges
- Temperature: 0 ... 50 °C /  32 ... 122 °F
- Relative humidity: 10 ... 90% r.h.
- Barometric pressure: 10 ... 1100 hPa (mbar)
- Selectable pressure unit: hPa, mmHg and inHg
- Real-time data storage
- incl. ISO Calibration Certificate
NDT Test Instruments PCE-2900-ICA incl. ISO Calibration Certificate
US$ 2,635.00
ex. VAT, ex. delivery costs
ISO Calibration

The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials. The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore. The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle. 

- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS 
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate

Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Material Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The material thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the material thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Moisture Meter PCE-HT 70-ICA incl. ISO Calibration Certificate
US$ 288.00
ex. VAT, ex. delivery costs
ISO Calibration
The moisture meter records the air temperature and humidity and stores them internally. The compact moisture meter with a large memory (up to a maximum of 16,000 values) is primarily used for long-term registration, for example in the food sector (e.g. refrigerated counters in supermarkets, refrigerated transport, warehouses) or in the industrial sector (heating and cooling processes, machine temperatures, product warehouses...)

- Measuring range temperature: -40 ... 85 °C / -40 ... 185 °F
- Measuring range rel. humidity: 0 ... 100%
- Max. 16,000 data records can be saved
- Export to software possible
- 450 day running time
- Adjustable storage rate from 1 second
- incl. ISO Calibration Certificate
NDT Tester - Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The NDT tester - thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the NDT tester - thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Class 1 SPL Meter PCE-432-SC 09-ICA with Calibrator incl. ISO Certificate
US$ 3,770.00
ex. VAT, ex. delivery costs
ISO Calibration
The Class 1 SPL Meter meets all requirements for noise measurement and frequency analysis. In addition to the sound measurement function, the SPL Meter is equipped with a GPS receiver. The GPS function allows the user to assign the measured values ​​to an exact position.

- Accuracy class 1
- GPS function
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Class 1 sound calibrator
- Incl. ISO Calibration Certificate (for sound calibrator)
Class 1 Noise Meter PCE-432-SC 09-ICA with Calibrator incl. ISO Certificate
US$ 3,770.00
ex. VAT, ex. delivery costs
ISO Calibration
The Class 1 Noise Meter meets all requirements for noise measurement and frequency analysis. In addition to the sound measurement function, the Noise Meter is equipped with a GPS receiver. The GPS function allows the user to assign the measured values ​​to an exact position.

- Accuracy class 1
- GPS function
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Class 1 sound calibrator