Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The ultrasonic flow meter has a measuring range of ±32 m/s. To perform flow measurement with the
ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
Pipe size:
  DN
 15 ... 100 / 20 ... 108 mm,
  DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity,
  volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 10 million measuring points
- LiPo battery
- incl. ISO Calibration Certificate
Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The ultrasonic flow meter has a measuring range of ±32 m/s. To perform flow measurement with the
ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
Pipe size:
  DN
 50 ... 700 / 57 ... 720 mm,
  DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity,
  volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 10 million measuring points
- LiPo battery
- incl. ISO-Calibration Certificate
Flow Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
US$ 3,419.00
ex. VAT, ex. delivery costs
ISO Calibration
The flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
- Sensor for pipe diameters DN 50 ... 700 / 57 ... 720 mm, DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO-Calibration Certificate
Multifunction Moisture Analyzer PCE-MA 110-ICA Incl. ISO Calibration Certificate
US$ 1,373.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-MA 110 is a halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.


- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate

Absolute Moisture Sensor PCE-MWM 230
US$ 5,214.00
ex. VAT, ex. delivery costs

VHF-Band Moisture sensor Crushed soil, sand, stone, Gravel, Ore. The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 250 °C. The moisture sensor probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture sensor can also be used for soil moisture control.


- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
  0 ... +90 °C (industrial version)
  0 ... +115 °C (extended temperature range)
  0 ... +250 °C (drying kilns)

 

Portable Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Data Logging Instrument PCE-830-3-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate

Outdoor Construction Noise Meter Kit PCE-432-EKIT-ICA incl ISO Calibration Cert.
US$ 6,917.00
ex. VAT, ex. delivery costs
ISO Calibration

The Class 1 outdoor construction noise meter kit PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor construction noise meter kit is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.

 

- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
Incl. ISO calibration certificate

Portable Ultrasonic Flow Meter PCE-TDS 200+ S-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- Sensor for pipe diameter DN 15 ... 100 / 20 ... 108 mm
- Sensor dimensions: 91 x 52 x 44 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Gloss Meter PCE-IGM 100-ICA incl. ISO calibration certificate
US$ 3,361.00
ex. VAT, ex. delivery costs
ISO Calibration

A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.


- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate

Absolute Moisture Sensor PCE-MWM 300P
US$ 5,610.00
ex. VAT, ex. delivery costs

For industrial continuous production of wood pellets, chips, sawdust and similar materials when on-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 300P moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.


- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: -40 ... +150 °C  (-40 ... +302 °F)
- Current consumption: 200 mA
- Power supply : 24 (18 ... 36) VDC
- Questionnaire starts evaluation process
- Application: pellets, wood chips

HVAC Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The HVAC thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the HVAC thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Absolute Moisture Sensor PCE-MWM 240-A
US$ 6,588.00
ex. VAT, ex. delivery costs

Designed specifically for use in humidity measurement of bulk materials, this moisture sensor is installed in bins, silos, troughs, bunkers case, distributors, augers and conveyors. Material in bulk or flowing mass, such as fibrous materials, gravel, sawdust, fly ash (mineral), wood chips (surface to 5 cm) feed grain, flour, seed, pastes, ... is continuously measurable.

- Stainless sensor rod (250 mm length)
- Lab analysis of your sample determines % error
- Measuring range: 0 ... 100%
- Material temperature range: -0 ... +80 °C  (+41 ... +176 °F)
- Analog and digital signal output

Absolute Moisture Sensor PCE-MWM 200
US$ 5,669.00
ex. VAT, ex. delivery costs

The moisture sensor is a sensor for measuring moisture of sand consisting of a central probe surrounded by four other probes. The probes and sensor housing are made of stainless steel AISI 321. Our moisture sensor is ideally suited for installation in tanks with liquid materials such as fuel oil, sludge from cement production, fuels (CWF).


- Readability mass fraction of water: 0 ... 100%
- Moisture measurement range: ± 0.1 ... 100% (water mass fraction))
- Maximum permissible absolute error moisture measurement: Varies by material, lab test required
- Temperature range: +5 ... +80 °C

Liquid Material Moisture Analyzer PCE-MWM 220
US$ 7,722.00
ex. VAT, ex. delivery costs

Moisture analyzers for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture analyzer for liquid materials has a processing unit with RS232/RS485 interfaces.


- Measurement range: 0 ... 100 %
- Limits of permissible absolute error of the measurements: Δ= 0,035 +0,05·W
- Temperature measurement range: -40 ... +150 °C

Absolute Moisture Sensor PCE-MWM 210
US$ 5,874.00
ex. VAT, ex. delivery costs

For industrial continuous production of wood pellets, chips, sawdust and similar materials when in-line moisture measurement for monitoring and controlling the mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 210 moisture sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.


- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: +5 ... +80 °C  (+41 ... +176 °F)
- Questionnaire starts evaluation process