The analytical balance PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the analytical balance dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
The Multifunction Moisture Analyzer PCE-MA 200 is used to weigh a range of substances up to 200g / 7.05oz and measure their moisture content. A halogen lamp heats up the chamber to 199 °C / 390 °F. The multifunction moisture analyzer dries the substance to be weighed within the heating chamber and determines the moisture content from the difference in weight.
- Weighing range: 200 g / 7.05 oz
- Resolution: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- Accuracy to 0.01 %
PCE-MA 110 is a tabletop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
The precision balance PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the precision balance dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
The precision balance PCE-MA 200 is used to weigh a range of substances up to 200g / 7.05oz and measure their moisture content. A halogen lamp heats up the chamber to 199 °C / 390 °F. The precision balance dries the substance to be weighed within the heating chamber and determines the moisture content from the difference in weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- Accuracy to 0.01 %
PCE-MA 100 is an oven-drying moisture analyzer for weighing and heating material samples to determine moisture content. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the moisture analyzer or moisture balance dries the sample to be weighed, and then calculates the moisture content from the weight difference.
- Weighing range110 g / 3.88 oz
- Moisture content measurement range: 0 ... 100 %
- Resolution: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- Memory for up to 15 drying programs
Moisture sensor for liquid materials are used in boiler installations, water-dosing and diesel oil emulsion dispersion systems. The scope of supply can include the control cabinet to operate the valves regulating water feed. The moisture sensor for liquid materials has a processing unit with RS232/RS485 interfaces.
- Measurement range: 0 ... 100 %
- Temperature range: +5 ... +80 °C (+41 ... +176 °F)
For industrial continuous production of wood pellets, chips, sawdust and similar materials when in-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: +5 ... +80 °C (+41 ... +176 °F)
- Questionnaire starts evaluation process
PCE-MA 110 is a benchtop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
PCE-MA 110 is a tabletop scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
PCE-MA 110 is a LAB scale or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
- RS-232 interface for connection to a PC
- incl. ISO Calibration Certificate
The absolute moisture meter PCE-MA 200 is used to weigh a range of substances up to 200g / 7.05oz and measure their moisture content. A halogen lamp heats up the chamber to 199 °C / 390 °F. The absolute moisture meter dries the substance to be weighed within the heating chamber and determines the moisture content from the difference in weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- Accuracy to 0.01 %
The wood moisture meter PCE-MA 200 is used to weigh a range of substances up to 200g / 7.05oz and measure their moisture content. A halogen lamp heats up the chamber to 199 °C / 390 °F. The wood moisture meter dries the substance to be weighed within the heating chamber and determines the moisture content from the difference in weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 1 mg / 0.001 g
- Adjustable drying temperature and time
- Accuracy to 0.01 %
For industrial continuous production of wood pellets, chips, sawdust and similar materials when in-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The PCE-MWM 210 moisture test sensor of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: +5 ... +80 °C (+41 ... +176 °F)