Food / Hygiene Meter PCE-HWA 30
US$ 359.00
ex. VAT, ex. delivery costs
The Food / Hygiene Meter measures the flow velocity according to the hot wire principle. This guarantees a particularly compact design. In addition to the flow rate, the Food / Hygiene Meter can measure the volume flow and the ambient temperature.

- Measuring range: 0.3 ... 30.0 m/s / 0.98 ... 98.4 ft/s
- Probe length: 270 … 990 mm / 10.63 … 38.98 / 29.1"
- Probe diameter: Ø0.8 ... 1.2 mm / 0.031 x 0.047"
- Data memory for 960 measured values
- Wind speed
- Volume flow
- Temperature measurement
Particle Counter PCE-PQC 35US Incl. Calibration Certificate
US$ 5,395.00
ex. VAT, ex. delivery costs
The particle counter PCE-PQC 35US is the most advanced particle counter on the market. This particle counter PCE-PQC 35US stores up to 45,000 measured values ​​with time stamp.

- Wall Mount Particle Counter with C02 & PID Sensor
- 6 channel measuring range 0.3(fixed) 0.4-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% at 0.5 μm 100% at > 0.75 μm according to JIS 
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (PM 2.5, PM 10)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Particle Counter PCE-PQC 10US Incl. Calibration Certificate
US$ 4,295.00
ex. VAT, ex. delivery costs
ISO Calibration
The particle counter PCE-PQC 10US quickly detects where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Handheld Particle Counter with 10 hour battery life continuous use
- 6 channel measuring range 0.3(fixed) 0.3-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (adjustablePM 2.5, PM 10 e.g.)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Food / Hygiene Meter PCE-HWA 30-ICA incl. ISO Calibration Certificate
US$ 552.00
ex. VAT, ex. delivery costs
ISO Calibration
The Food / Hygiene Meter measures the flow velocity according to the hot wire principle. This guarantees a particularly compact design. In addition to the flow rate, the Food / Hygiene Meter can measure the volume flow and the ambient temperature.

- Measuring range: 0.3 ... 30.0 m/s / 0.98 ... 98.4 ft/s
- Probe length: 270 … 990 mm / 10.63 … 38.98 / 29.1"
- Probe diameter: Ø0.8 ... 1.2 mm / 0.031 x 0.047"
- Data memory for 960 measured values
- Wind speed
- Volume flow
- Temperature measurement
- incl. ISO Calibration Certificate (wind speed function only)
Particle Counter PCE-PQC 12US Incl. Calibration Certificate
US$ 2,995.00
ex. VAT, ex. delivery costs
ISO Calibration
The particle counter PCE-PQC 12US quickly detects where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Handheld Particle Counter with 10 hour battery life continuous use
- 3 channel measuring range 0.3(fixed) 0.3-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (adjustablePM 2.5, PM 10 e.g.)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Particle Counter PCE-PQC 11US Incl. Calibration Certificate
US$ 4,095.00
ex. VAT, ex. delivery costs
ISO Calibration
The particle counter PCE-PQC 11US quickly detects where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Handheld Particle Counter with 10 hour battery life continuous use
- 6 channel measuring range 0.5(fixed) 0.5-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% @ 0.5 μm; 100% for particles >0.75 μm per JIS
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (adjustablePM 2.5, PM 10 e.g.)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Food / Hygiene Meter PCE-HWA 20BT
US$ 297.00
ex. VAT, ex. delivery costs
Wireless
The Food / Hygiene Meter has a measuring range of 0 ... 30 m / s. In addition to the air flow, the Food / Hygiene Meter can also measure the ambient temperature between -20 ... 60°C / -4 ... 140°F and the ambient humidity between 0 ... 100% RH.

- Wind speed measuring range: 0.00 ... 30.00 m / s
- Temperature measuring range: -20 ... 60°C / -4 ... 140° F
- Humidity measuring range: 0 ... 100% RH
- Telescope diameter 12 mm
- 390 mm / 15.4 in telescopic pole
- Bluetooth 4.0 interface
Food / Hygiene Meter PCE-HWA 20BT-ICA incl. ISO Calibration Certificate
US$ 488.00
ex. VAT, ex. delivery costs
ISO Calibration
The Food / Hygiene Meter has a measuring range of 0 ... 30 m/s. In addition to the air flow, the Food / Hygiene Meter can also measure the ambient temperature between -20 ... 60 °C / -4 ... 140 °F and the ambient humidity between 0 ... 100% RH.

- Wind speed measuring range: 0.00 ... 30.00 m/s / 98 ft/s / 67 mph
- Temperature measuring range: -20 ... 60 °C / -4 ... 140 °F
- Humidity measuring range: 0 ... 100% RH
- Telescope diameter 12 mm / 0.47"
- 390 mm / 15.4" telescopic pole
- Bluetooth 4.0 interface
- incl. ISO Calibration Certificate (wind speed function only)
NDT Test Instrument PCE-VE 1500-22190
US$ 30,657.00
ex. VAT, ex. delivery costs
Wireless
With this NDT test instrument, weld seams, wear and tear and damage can be assessed quickly and easily in order to make quick diagnoses. The sheathing of the endoscope cable from the NDT test instrument consists of braided tungsten.

- Diameter: Ø2.2mm / 0.08"
- Cable length: 1m / 3.2 ft
- Camera direction: 90°
- Resolution: 160,000 pixels
- Focusing range: 5 ... 50 mm / 0.19 ... 1.96"
- 7" touch screen for easy operation
- replaceable battery with status display
- Storage of recording on SD card
- Motor with endoscope cable can be changed quickly
- HDMI connection for direct image transmission
Particle Counter Dust Measuring Device PCE-CPC 100
US$ 6,137.00
ex. VAT, ex. delivery costs
Topseller
The state-of-the-art particle counter dust measuring device  enables precise real-time measurement in the range of 0.3 μm to 10 μm to provide a comprehensive picture of air quality. The results are presented in two units, either number per 28.3 litres or number per cubic metre. Air sampling from the particle counter dust measuring device  is done by an internal pump.

Real-time measurement from 0.3 μm ... 10 μm
Output in particles/28.3L or particles/m³
- Visual and audible alarm
  when threshold value is exceeded
- Modbus RTU and MQTT via RS485
- Temperature and humidity measurement
Real-time display of clean room class
  ISO 14644-1
NDT Test Instrument PCE-VE 1500-38209
US$ 30,657.00
ex. VAT, ex. delivery costs
Wireless
With this NDT test instrument, weld seams, wear and tear and damage can be assessed quickly and easily in order to make quick diagnoses. The sheathing of the endoscope cable from the NDT test instrument consists of braided tungsten.

- Endoscope cable length: approx. 2 m / 6.5 ft
- Diameter: 3.8mm / 0.15"
- Camera resolution 160,000 pixels each
- Viewing angle front camera 120°, side camera 90°
- Focusing distance 5 … 50 mm / 0.19 ... 1.96" each
- Camera head length: 42 mm / 1.6"
- Bending radius at 90° 35 mm / 1.3"
- Live images from both cameras side by side
- 7" touch screen for easy operation
- Replaceable battery with status display
- Storage of recording on SD card
- Motor with endoscope cable can be changed quickly
- HDMI connection for direct image transmission
Particle Counter PCE-PQC 30US Incl. Calibration Certificate
US$ 4,295.00
ex. VAT, ex. delivery costs
The particle counter PCE-PQC 30US is the most advanced particle counter on the market. Integration into a building automation and clean room management system is easily possible via Ethernet or (optionally) Wireless 802.11 b / g, RS485 or RS232.

- Wall Mount Particle Counter
- 6 channel measuring range 0.3(fixed) 0.4-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% at 0.5 μm 100% at > 0.75 μm according to JIS 
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (PM 2.5, PM 10)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Particle Counter PCE-PQC 31US Incl. Calibration Certificate
US$ 4,095.00
ex. VAT, ex. delivery costs
The particle counter PCE-PQC 31US can be remotely controlled and monitored via a web browser. The particle counter PCE-PQC 31US is a mounting device for rod or wall mounting.

- Wall Mount Particle Counter
- 6 channel measuring range 0.5(fixed) 0.6-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% at 0.5 μm 100% at > 0.75 μm according to JIS 
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (PM 2.5, PM 10)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Particle Counter PCE-CPC 50
US$ 2,495.00
ex. VAT, ex. delivery costs
Topseller
The state-of-the-art particle counter enables precise real-time measurement in the range of 0.3 μm to 10 μm to provide a comprehensive picture of air quality. The results are presented in two units, either in number per m³, number per litre or number per 28.3l. Air sampling from the particle counter is performed by an internal pump.

- Particle concentration:  0.3  ... 10 μm
- Particle measurement channel sizes: 
  0.3, 0.5, 1.0, 2.5, 5.0, 10 µm
- Output in particles/m³, 
  particles/l or particles/28.3L
- Modbus RTU and MQTT via RS485
- Analogue output 4 . .. 20 mA
Airflow Food / Hygiene Meter PCE-423N
US$ 263.00
ex. VAT, ex. delivery costs
The airflow food / hygiene meter has a measuring range of up to 0 ... 30 m/s. In addition to the velocity, the airflow food / hygiene meter can precisely measure the volume flow and temperature. The compact design of the sensors, in combination with the extendable telescopic probe, enable measurements to be taken even in places that are particularly difficult to access.

- Speed: 0.00 ... 30.00 m/s / 0.00 ... 98.42 ft/s
- Volume flow: 0.0 ... 339120.0 m3/h
- Temperature: 0 ... 50 °C / 32 ... 122 °F
- Telescopic probe length: 210 ... 426 mm / 8.2 ... 16.7"
- Telescopic probe diameter: 12 mm / 0.47"
NDT Test Instrument PCE-VE 1500-28200
US$ 26,393.00
ex. VAT, ex. delivery costs
Wireless
With this NDT test instrument, weld seams, wear and tear and damage can be assessed quickly and easily in order to make quick diagnoses. The sheathing of the endoscope cable from the NDT test instrument consists of braided tungsten.

- Diameter: Ø2.8mm / 0.11"
- Cable length: 2m / 6.5 ft
- Camera direction: 0°
- Resolution: 160,000 pixels
- Focusing range: 5 ... 50 mm / 0.19 ... 1.96"
- 7" touch screen for easy operation
- Replaceable battery with status display
- Storage of recording on SD card
- Motor with endoscope cable can be changed quickly
- HDMI connection for direct image transmission
Air Quality Station / Air Quality Monitor PCE-RCM 12
US$ 607.00
ex. VAT, ex. delivery costs
The air quality station is used for indicative testing of environmental parameters. The air quality station enables the measurement of CO2, fine dust, temperature and relative humidity. The bright display of the air quality station provides information about these parameters. 


- Fine dust, CO2, formaldehyde, humidity, temperature
- Particle size channels: PM 2.5 / PM 10
- Temperature measuring range: -20 ... 70°C / -4 ... 158°F
- Humidity measuring range: 0 ... 100% r.H.
- Formaldehyde measuring range: 0.00 ... 5.00 mg/m³
- CO2 measuring range: 0 ... 9999 ppm
- For indicative measurements
NDT Test Instrument PCE-VE 1500-60500
US$ 25,773.00
ex. VAT, ex. delivery costs
Wireless
With this NDT test instrument, weld seams, wear and tear and damage can be assessed quickly and easily in order to make quick diagnoses. The sheathing of the endoscope cable from the NDT test instrument consists of braided tungsten.

- Diameter: Ø6mm / 0.23"
- Cable length: 5m / 16.4 ft
- Camera direction: 0°
- Resolution: 1MP
- Focusing range: 5 ... 50 mm / 0.19 ... 1.96"
- 7" touch screen for easy operation
- replaceable battery with status display
- Storage of recording on SD card
- Motor with endoscope cable can be changed quickly
- HDMI connection for direct image transmission