Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
- Sensor for pipe diameters DN 50 ... 700 / 57 ... 720 mm, DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO-Calibration Certificate
Environmental Tester PCE-EMD 5-ICA incl. ISO Calibration Certificate
US$ 1,319.00
ex. VAT, ex. delivery costs
ISO Calibration
The environmental tester can be connected to up to four external temperature and humidity modules. The temperature measuring range for the thermometer sensors is 0.0 … 50.0 °C and the humidity measuring range is 0.0… 99.9% RH.

- Temperature measuring range: 0.0 … 50.0 °C
- Humidity measuring range: 0.0 ... 99.9% RH
- Connection of up to four external sensors
- Analog 4 ... 20 mA input signal
- Wall mounting
- incl. ISO Calibration Certificate
Environmental Meter PCE-DPM 3-ICA
US$ 1,513.00
ex. VAT, ex. delivery costs
ISO Calibration
The environmental meter is a mobile testing device for monitoring the quality of compressed air on stationary and mobile compressed air generators. This environmental meter measures the temperature, the relative humidity, H2O and calculates the current dew point up to an ambient pressure of 20 bar.

- Dew point, H2O, temperature, humidity measurement
- Data memory for approx. 50,000 measurement data
- CSV data export
- With G1 / 2" connection thread
- For inline measurement of pressure pipes
- Sensor protected with a cap
- Left connection has NO function
- incl. ISO Calibration Certificate for humidity and temperature
Portable Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Data Logging Instrument PCE-830-3-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate

Portable Ultrasonic Flow Meter PCE-TDS 200+ S-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- Sensor for pipe diameter DN 15 ... 100 / 20 ... 108 mm
- Sensor dimensions: 91 x 52 x 44 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Environmental Meter PCE-322ALEQ-ICA incl. ISO Calibration Certificate
US$ 713.00
ex. VAT, ex. delivery costs
ISO Calibration
The environmental meter PCE-322A is particularly suitable for measuring noise in the field of industrial, health, safety and environmental monitoring. The PCE-322A environmental meter has a logger function, which allows storage of up to 32700 readings.


- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
- incl. ISO calibration certificate

Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.

Gloss Meter PCE-IGM 100-ICA incl. ISO calibration certificate
US$ 3,361.00
ex. VAT, ex. delivery costs
ISO Calibration

A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.


- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate

Moisture Meter PCE-MA 60XT-ICA incl. ISO calibration certificate
US$ 3,405.00
ex. VAT, ex. delivery costs
The precision moisture meter enables moisture determinations with a resolution of 0.001 %. The operation of this moisture meter is very simple. Set the drying temperature, place the sample and start drying.

- Weighing range: 60 g
- Readability: 0.1 mg = 0.0001 g / 0.001%
- Drying temperature up to 160°C
- Live graph of moisture content
- Display: Moisture content % / Dry content % / ATRO % / Weight
- Product database for drying parameters
- RS232 / USB interface
- Storage as TXT file directly on USB stick possible
incl. ISO calibration certificate

- Attention to the power supply when ordering!
Environmental Tester PCE-BPH 20-ICA incl. ISO Calibration Certificate
US$ 1,254.00
ex. VAT, ex. delivery costs
ISO Calibration
The table-top environmental tester can be used to quickly and precisely analyze liquid samples. Thus, for example, water, alkalis, milk, wine and many other liquids can be checked for their quality with the environmental tester.

Measuring range:
- pH, mV, TDS
- Temperature, conductivity
- Salinity, resistance
- Large 7" touchscreen
- Bluetooth and USB interfaces
- 3 point calibration
- incl. ISO Calibration Certificate (for PH value only)
Environmental Meter PCE-HT 120
US$ 296.00
ex. VAT, ex. delivery costs
The environmental meter PCE-HT 120 is used to measure temperature and humidity. The measurement data from the environmental meter are displayed in an app on the tablet or smartphone and the display.

Measuring function
- Humidity
- Temperature
- Dew point
- Wet bulb temperature
- Ethernet: WLAN / WIFI
- Accespoint and client mode
- Connection for external PT1000 sensor
HVAC Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
US$ 3,419.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.


- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate

NDT Test Instruments PCE-2900-ICA incl. ISO Calibration Certificate
US$ 2,635.00
ex. VAT, ex. delivery costs
ISO Calibration

The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials. The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore. The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle. 

- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS 
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate

Class 1 Decibel Meter PCE-430-SC 09-ICA incl. ISO Calibration Certificate
US$ 3,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The class 1 decibel meter PCE-430-SC 09-ICA meets all requirements for noise measurement and frequency analysis. This integrating precision pulse decibel meter complies with all applicable standards and guidelines.

- Accuracy class 1
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. class 1 sound calibrator
- Incl. ISO calibration certificate (for sound calibrator)
Class 1 SPL Meter PCE-430-SC 09-ICA incl. ISO Calibration Certificate
US$ 3,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The class 1 SPL meter PCE-430-SC 09-ICA meets all requirements for noise measurement and frequency analysis. This integrating precision pulse SPL meter complies with all applicable standards and guidelines.

- Accuracy class 1
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. class 1 sound calibrator
- Incl. ISO calibration certificate (for sound calibrator)
Class 1 Noise Meter PCE-430-SC 09-ICA incl. ISO Calibration Certificate
US$ 3,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The class 1 noise meter PCE-430-SC 09-ICA meets all requirements for noise measurement and frequency analysis. This integrating precision pulse noise meter complies with all applicable standards and guidelines.

- Accuracy class 1
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. class 1 sound calibrator
- Incl. ISO calibration certificate (for sound calibrator)
Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Material Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The material thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the material thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate