The PCE-830 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The Class 1 outdoor construction noise meter kit PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor construction noise meter kit is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The class 2 outdoor sound level meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc.
The outdoor sound level meter is equipped with an octave band frequency filter.
Optionally, the outdoor sound level meter can be upgraded with a 1/3 octave band filter.
The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The class 2 outdoor decibel meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor decibel meter is equipped with an octave band frequency filter. Optionally, the outdoor decibel meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a decibel meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The class 2 outdoor noise dose meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor noise dose meter is equipped with an octave band frequency filter. Optionally, the outdoor noise dose meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a noise dose meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The class 2 outdoor SPL meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor SPL meter is equipped with an octave band frequency filter. Optionally, the outdoor SPL meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The class 2 outdoor aircraft noise meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor aircraft noise meter is equipped with an octave band frequency filter. Optionally, the outdoor aircraft noise meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with an aircraft noise meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The PCE-830 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The environmental tester is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental tester has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The PCE-830-3 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-830-3 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate