PCE-MA 110 is a halogen moisture test instrument or analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
- Incl. ISO calibration certificate
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate
PCE-VC21 is a vibration calibrator used to calibrate vibration sensors, meters, analyzers and testers. Suitable for calibrating equipment weighing up to 600 g (1.32 lb), this rechargeable-battery-powered vibration calibrator generates mechanical vibrations with adjustable quartz-stabilized vibration frequencies between 15.92 and 1280 Hz and adjustable vibration amplitudes between 1 m/s² and 20 m/s².
- Load-independent vibration magnitude
- 7 adjustable vibration frequencies
- 5 adjustable vibration amplitudes
The NDT test Instrument PCE-VE 1030N is a versatile videoscope or video borescope inspection camera with a large 7" high-resolution display. This NDT test Instrument captures and stores both picture and video. Video recordings are accompanied by audio for a more immersive inspection experience.
- Cable length: 30 m / 98 ft
- Camera head diameter: 28 mm / 1.1 in
- SD card memory included
- Waterproof cable and camera
The condition monitoring sound level meter is a class 2 (type 2) sound level, sound pressure level (SPL), decibel (dB) or noise meter with audible or visual alarm output capability. The condition monitoring sound level meter is used for long-term, continuous monitoring of occupational noise exposure limits in industrial environments. Powered by AC current.
- Measuring range: 30 ... 130 dB in 3 ranges
- Resolution: 0.1 dB
- Accuracy: ±1.5 dB
- Class 2 and frequency weighting: A
- Output: 4 ... 20-mA and alarm relay output of 5 A / up to 240V AC
- IP 54 ingress protection rating on transmitter
- Includes digital indicator with IP 65 rating
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The NDT test Instrument PCE-VE 1030N is a versatile videoscope or video borescope inspection camera with a large 7" high-resolution display. This NDT test Instrument captures and stores both picture and video. Video recordings are accompanied by audio for a more immersive inspection experience.
- Cable length: 30 m / 98 ft
- Camera head diameter: 28 mm / 1.1 in
- SD card memory included
- Waterproof cable and camera
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- incl. ISO Calibration Certificate
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The Electrical Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This Electrical Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
PCE-VC21 is a portable shaker vibration calibrator used to calibrate vibration sensors, meters, analyzers and testers. Suitable for calibrating equipment weighing up to 600 g (1.32 lb), this rechargeable-battery-powered vibration calibrator generates mechanical vibrations with adjustable quartz-stabilized vibration frequencies between 15.92 and 1280 Hz and adjustable vibration amplitudes between 1 m/s² and 20 m/s².
- Load-independent vibration magnitude
- 7 adjustable vibration frequencies
- 5 adjustable vibration amplitudes