This device is a Three-Phase Power Meter / 3-Phase Power Analyzer with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
The data logger PCE-PDA 1000L measures the relative pressure on machines and systems. The relative pressure is measured by this data logger in the range between -100 ... 2000 kPa. The data logger PCE-PDA 1000L has a quick coupling connection with which the air pressure or water pressure can be directly applied to the device.
- Measuring range pressure: -100 ... 2000 kPa relative / -14.5 ... 290 PSI
- Resolution: 0.01 kPa, 0.1 kPa
- Accuracy: <± 0.5% of the measuring range
- USB interface
- Data logger
- Adjustable measuring units: Pa, hPa, kPa, MPa, mbar, bar, ATM, kg / cm², mmH2O, cmH2O, inH2O, mmHg, inHg, Torr, PSI, PSF
The PCE-830 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
PCE-T 1200 is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the temperature data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
This 12-channel temperature data logger accommodates SD cards up to 16 GB in size. The optional software allows the temperature meter to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The PCE-HT110 Humidity / Temperature Data Logger or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110 is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
The PCE-830 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830-3 3-Phase Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter / 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate