Current Clamp PCE-PA 8300-2
US$ 3,098.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Current Clamp is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Data Logger PCE-PCO 2
US$ 1,524.00
ex. VAT, ex. delivery costs

PCE-PCO 2 is a portable handheld data logger used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this data logger also measures air temperature, dew point and relative humidity.


- PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
- Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Temp. measuring range: 0 ... +50 °C / +32 ... +122 °F
- Humidity measuring range: 0 ... 100 % RH
- Built-in camera for image and video recording
- Free software download on PCE Software web page


Current Clamp PCE-PA 8300-1
US$ 2,947.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Current Clamp is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Data Logger PCE-MPC 30
US$ 1,436.00
ex. VAT, ex. delivery costs
This Data Logger has many functions. With the Data Logger it is possible to determine the number of particles in the size of 0.3, 2.5 and 10 µm.
 
- Measurable particle sizes:  PM 2.5 and PM 10
- Measuring range: 0 ... 2000 µg / m³
- Resolution: 1 µg / m³
- Particle counter, HCHO, temperature measurement
- Dew point and wet bulb temperature
Electrical Tester PCE-PA 8300-2
US$ 3,098.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Electrical Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Three-Phase Power Meter PCE-830-2
US$ 3,557.00
ex. VAT, ex. delivery costs

The 3-Phase-Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase-Power Meter / 3-Phase Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

Clamp Meter PCE-PA 8300-2
US$ 3,098.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Clamp-On Tester PCE-PA 8300-2
US$ 3,098.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp-On Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Data Logger PCE-MPC 25
US$ 1,385.00
ex. VAT, ex. delivery costs
The data logger is used in offices, workshops or in laboratories to carry out indicative measurements of the environmental conditions. In addition to the number of particles, the data logger determines the mass concentration of PM2.5 and PM10 in the measuring range 0 … 1000 µg/m³.

- Measurable particle sizes: PM2.5 / PM10
- Particle sizes: 0.3 / 0.5 / 1.0 / 2.5 / 5.0 and 10 µm
- Mass concentration
- Particle counter
- Temperature
- Humidity (RH)
- Flash memory for approx. 12 measurement runs
Multi Channel Temperature Data Logger PCE-T 1200-ICA incl. ISO Calibration Certificate
US$ 2,415.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-T 1200 is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the temperature data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel. 

- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel

Includes 2 Type K sensors 1-meter in length
- incl. ISO Calibration Certificate

Sound Level Data Logger PCE-428
US$ 1,518.00
ex. VAT, ex. delivery costs

The Data Logger PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The data logger calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Electrical Tester PCE-PA 8300-1
US$ 2,947.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Electrical Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Three-Phase Power Meter PCE-830-1
US$ 3,155.00
ex. VAT, ex. delivery costs

The 3-Phase-Power Meter / 3-Phase Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase-Power Meter / 3-Phase Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

 

Three-Phase Power Meter PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The Three-Phase Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three-Phase Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. 


- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)

Clamp-On Tester PCE-PA 8300-1
US$ 2,947.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp-On Tester is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Clamp Meter PCE-PA 8300-1
US$ 2,947.00
ex. VAT, ex. delivery costs

The easy-to-use PCE-PA 8300 Clamp Meter is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:


- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage

Data Logger PCE-PCO 1
US$ 1,241.00
ex. VAT, ex. delivery costs
Topseller

PCE-PCO 1 is a handheld data logger for measuring the concentration of particles in the air. The PCE-PCO 1 data logger:


- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust, 80 MB internal memory
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
  humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)

Dew Point Data Logger PCE-DPM 3
US$ 1,359.00
ex. VAT, ex. delivery costs
The dew point data logger is a mobile testing device for monitoring the quality of compressed air on stationary and mobile compressed air generators. This dew point data logger measures the temperature, the relative humidity, H2O and calculates the current dew point up to an ambient pressure of 20 bar.

- Dew point, H2O, temperature, humidity measurement
- Data memory for approx. 50,000 measurement data
- CSV data export
- With G1 / 2" connection thread
- For inline measurement of pressure pipes
- Sensor protected with a cap
- Left connection has NO function