Data Logger PCE-830-2
US$ 3,557.00
ex. VAT, ex. delivery costs

The PCE-830-2 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

Outdoor Sound Level Data Logger PCE-428-EKIT
US$ 5,379.00
ex. VAT, ex. delivery costs

The class 2 outdoor sound level data logger PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor sound level data logger is equipped with an octave band frequency filter. Optionally, the outdoor sound level data logger PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise

Data Logger PCE-830-1
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)

Data Logger PCE-830-3
US$ 3,155.00
ex. VAT, ex. delivery costs

The PCE-830-3 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.


- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)

Three-Phase Power Analyzer PCE-PA 8500
US$ 4,326.00
ex. VAT, ex. delivery costs
The three-phase power analyzer redefines standards in electrical measurement technology, offering a comprehensive range of features for precise and detailed measurements. The three-phase power analyzer allows accurate measurements of electrical voltage, current, frequency, harmonics, and starting currents. In addition, precise power and energy measurements can be performed, enabling accurate monitoring and optimization of energy consumption.

- Voltages: 1 ... 1000 V
- Current: 15 ... 3000 A AC
- Graphical representation of waveform and vector graphics
- Data logger with 8 GB storage
- LAN and USB data interface
- Includes flexible current clamps
- Compliance with standards: IEC61000-4-30, 61000-4-15, 
  61000-4-7, EN50160
Data Logger with USB Interface PCE-428-EKIT
US$ 5,379.00
ex. VAT, ex. delivery costs

The data logger with USB interface PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is a class 2 device and is equipped with an octave band frequency filter. Optionally, the data logger with USB interface PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise

Outdoor Sound Level Data Logger PCE-428-EKIT-ICA incl. ISO Calibration Cert.
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The class 2 outdoor sound level data logger PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor sound level data logger is equipped with an octave band frequency filter. Optionally, the outdoor sound level data logger can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level data logger over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

IoT Data Logger PCE-432-EKIT-ICA incl ISO Calibration Certificate
US$ 6,917.00
ex. VAT, ex. delivery costs
ISO Calibration

The Class 1 IoT data logger can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The IoT data logger is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.

 

- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
Incl. ISO calibration certificate

Power Data Logger PCE-360-ICA incl. ISO Calibration Certificate
US$ 2,600.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.


- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB 
  (non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
incl. ISO Calibration Certificate 
incl. ISO Calibration Certificate 

Vibration Data Logger PCE-VM 5000-KIT
US$ 3,761.00
ex. VAT, ex. delivery costs

The 4-channel PCE-VM 5000 vibration data logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.


- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration

Vibration Data Logger PCE-VM 22
US$ 3,545.00
ex. VAT, ex. delivery costs
The vibration data logger has a measuring range of 0 ... 200 m/s² for acceleration. In addition to acceleration, the vibration data logger can also perform speed, displacement, frequency and an ISO 18016-3 measurement.

- Acceleration
- Velocity
- Displacement
- Frequency
- Tachometer    
- Infrared temperature measurement   
- 4 GB data memory
- FFT analysis and wave view of the vibration
Dew Point Data Logger PCE-DPM 10-SFKIT incl. Smart Features
US$ 5,438.00
ex. VAT, ex. delivery costs
The climate meter from PCE Instruments enables precise determination of the dew point in pressurised systems. Thanks to its robust design, the device can be used for industrial applications up to 15 bar.

- Dew point measuring range from -100 ... +50 °C
- Pressure range up to 15 bar differential pressure
- Data logger for up to 100 million measured values
- Adjustable alarm limits
- Touch LC display
Smart features:
- Prediction of the final dew point value
- Camera function
- PDF report function in accordance with ISO 8573-1
Sound Level Data Logger with GPS PCE-432
US$ 3,069.00
ex. VAT, ex. delivery costs

The Sound Level Data Logger PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Three-Phase Power Analyzer PCE-PA 8500-ICA incl. ISO-Calibration Certificate
US$ 4,897.00
ex. VAT, ex. delivery costs
ISO Calibration
The three-phase power analyzer redefines standards in electrical measurement technology, offering a comprehensive range of features for precise and detailed measurements. The three-phase power analyzer allows accurate measurements of electrical voltage, current, frequency, harmonics, and starting currents. In addition, precise power and energy measurements can be performed, enabling accurate monitoring and optimization of energy consumption.

- Voltages: 1 ... 1000 V
- Current: 15 ... 3000 A AC
- Graphical representation of waveform and vector graphics
- Data logger with 8 GB storage
- LAN and USB data interface
- Includes flexible current clamps
- Compliance with standards: IEC61000-4-30, 61000-4-15, 
  61000-4-7, EN50160
- incl. ISO-Calibration Certificate
Vibration Data Logger PCE-VM 5000
US$ 2,924.00
ex. VAT, ex. delivery costs

The 4-channel PCE-VM 5000 Data Logging Instrument performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested. These Data Logging Instrument are manufacturer calibrated. An ISO calibration certificate is an option.


- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card

 

Sound Level Data Logger PCE-430
US$ 2,837.00
ex. VAT, ex. delivery costs
The class 1 sound level data logger meets all requirements for noise measurement and frequency analysis. This integrating precision pulse sound level data logger complies with all applicable standards and guidelines.

- Accuracy class 1
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
Vibration Data Logger PCE-VM 5000-KIT-ICA incl. ISO Calibration Certificate
US$ 4,355.00
ex. VAT, ex. delivery costs
ISO Calibration

The 4-channel PCE-VM 5000 Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.


- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
- Including ISO Calibration Certificate

Data Logger PCE-CPC 50
US$ 2,495.00
ex. VAT, ex. delivery costs
Topseller
The state-of-the-art data logger enables precise real-time measurement in the range of 0.3 μm to 10 μm to provide a comprehensive picture of air quality. The results are presented in two units, either in number per m³, number per litre or number per 28.3l. Air sampling from the data logger is performed by an internal pump.

- Particle concentration:  0.3  ... 10 μm
- Particle measurement channel sizes: 
  0.3, 0.5, 1.0, 2.5, 5.0, 10 µm
- Output in particles/m³, 
  particles/l or particles/28.3L
- Modbus RTU and MQTT via RS485
- Analogue output 4 . .. 20 mA