The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
Data logger to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of airflow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
PCE-432 is a class 1 data-logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to an exact geographic location.
- Measuring range: 22 ... 136 db(A)
- A, B, C and Z frequency weightings
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-432 is a class 1 data-logging sound pressure level (SPL) meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to an exact geographic location.
- Measuring range: 22 ... 136 db(A)
- A, B, C and Z frequency weightings
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
The Data Logger with microprocessor is a high precision 1-channel temperature gauge. The Data Logger with microprocessor is ideal for use with various Pt100 sensors. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- 1 channel temperature recorder
- Automatic shutdown
- High accuracy of ± 2% r.H.
- Sampling rate of 2 / sec
- Memory size: 5,000 values
PCE-VDR 10-ICA is a single-axis accelerometer or shock data logger with real-time measurement and data logging capabilities. This shock data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this shock data logger compatlble with control systems.
- Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
- incl. ISO Calibration Certificate
PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
Data logger to measure air temperature and velocity with calculation of volume of air current and RS-232. These logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0°C / 32 ... 122°F (sensor)
- Volume of air current: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Sampling rate: 1 sec
The data logger for temperature and humidity detects air temperature and humidity and stores readings to its internal memory. This data logger for temperature and humidity is compact and has enough memory to store up to 32,000 readings, 16,000 for each parameter, and is used above all as a data logger, in supermarket refrigeration units, refrigerated transport, warehouses and other temperature controlled environments. These temperature and humidity logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Measurement range: 0 ... 100% RH / -35 ... 80°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The PCE-JR-911 Data Logger with logging function is a versatile tool in that it can measure the temperature of objects without contact and readings can be stored in memory and transferred to a computer by way of its RS-232 interface and software. This Data Logger comes complete, allowing the user to program specific time intervals for taking measurements, such as over an entire week. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Temperature range: -40 to 500°C / -40 ... 932°F
- Resolution: 0.1°C / 0.18°F
- Accuracy: ±2% of reading or ±2°C / 3.6°F
- Optical resolution: 8:1
- Emissivity: 0.3 to 1.0 (adjustable)
- Interface: RS-232
- Display: LCD