The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement
The Data Logger PCE-WL 1 is an ideal tool to measure and store the wind speed over a long period of time. The battery operation enables you to use the weather station for mobile applications. Since a wind turbine or wind power station is an expensive investment, you usually want to know what profits it will generate in advance. The Data Logger PCE-WL1 helps you determine these profits. These logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Measuring range: 0.8 ... 40 m/s
- Accuracy: ± 0.5 m/s or 5% of measurement value
- Battery life up to 3 years
- 512 MB microSD card incl.
The PCE-HT 71N Data Logger detects air temperature and humidity and stores readings to its internal memory. This Data Logger is compact and has enough memory to store up to 32,000 readings, 16,000 for each parameter, and is used above all as a Data Logger, in supermarket refrigeration units, refrigerated transport, warehouses and other temperature controlled environments. These temperature and humidity logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Measurement range: 0 ... 100% RH / -35 ... 80°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
The data logger for temperature and humidity precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The data logger for temperature and humidity is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
PCE-VDR 10-ICA is a single-axis accelerometer or vibration data logger monitor with real-time measurement and data logging capabilities. This vibration data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this vibration data logger compatlble with control systems.
- Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
- incl. ISO Calibration Certificate
This power datalogger is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics up to 50º of the harmonic waveform. The power analyzer clamp is equipped with data logger. The test instrument is delivered manufacturer ISO calibrated.
- Real-time test, register and measurement of voltage and current (real and effective)
- Measures power factor and phase angle, frequency, energy, active, reactive and apparent power
(single-phase or three-phase in symmetrical networks).
- Max. conductor diameter: 55 mm / 2.2 in
- Datalogger for 50,000 readings / software/ USB interface
- incl. ISO Calibration Certificate
PCE-VDR 10 is a single-axis accelerometer or shock data logger with real-time measurement and data logging capabilities. This single-axis shock data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this shock data logger compatlble with control systems.
- Single-axis Acceleration measuring range:
0.5 ... 199.9 m/s, 0.05 ... 20.39 g, 2 ... 656 ft/s
- Velocity measuring ranges:
0.5 ... 199.9 mm/s, 0.05 ... 19.99 cm/s, 0.02 ... 7.87 in/s
- Frequency range: 10 ... 1000 Hz
- Analog output: 4 ... 20 mA
- RS-232 and USB interface
The PCE-T390 multi channel temperature data logger is a digital device with four input channels for type K and type J temperature sensors and two input channels for PT100 temperature sensors. The PCE-T390 multi channel data logger has a SD card slot (from 1 ... 16 GB) for storing the measured data. The data is stored in xls format on the SD card of the data logger so that no additional software is needed for further analysis. This temperature logging test instrument comes manufacturer calibrated. An ISO calibration certificate can be purchased as an optional accessory.
- 4 input channels for type-K, J temperature sensors
- 2 input channels for Pt100 temperature sensors
- 2 x type-K TF-500 temperature sensors are included in the package
- Sampling rate of 1 sec.
- SD card memory (1 ... 16 GB)
The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.
- Measuring range: SPL: Auto 30 ... 130 dB
- Resolution: 0.1 dB
- Low sampling rate
- Automatic or manual storage
- Selectable storage interval
- Backlit LC display
- Dose measurement or SPL measurement