- Wall Mount Particle Counter with C02 sensor
- 6 channel measuring range 0.3(fixed) 0.4-25
um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% at 0.5 μm 100% at
> 0.75 μm according to JIS
- ISO 14644-1, EU GMP Annex I, FS
209E
- Mass concentration mode (PM 2.5, PM
10)
- Ethernet, USB, Touch Screen display, Audible
Alarms & Wifi Optional
- Incl. calibration certificate
traceable to NIST ISO 21501-4 and JIS B9921
- Made in the USA
PCE-5000 is a portable material hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
- Wall Mount Particle Counter with C02 & PID Sensor
- 6 channel measuring range 0.3(fixed) 0.4-25
um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% at 0.5 μm 100% at
> 0.75 μm according to JIS
- ISO 14644-1, EU GMP Annex I, FS
209E
- Mass concentration mode (PM 2.5, PM
10)
- Ethernet, USB, Touch Screen display, Audible
Alarms & Wifi Optional
- Incl. calibration certificate
traceable to NIST ISO 21501-4 and JIS B9921
- Made in the USA
PCE-VS11 is a vibration meter, analyzer or sensor condition monitoring switch used to measure RMS value, peak value and frequency domain (FFT) of vibration velocity or acceleration piezoelectrically. This IP67-rated vibration monitoring switch features a red and green visual warning or alarm with programmable high pass and low pass filters.
- Frequency range (max.): 0.1 Hz ...10 kHz
- Measuring range: Acceleration = 0.1 ... 1000 m/s², Speed =
Frequency-dependent
- Connections: Screw terminals for power supply (5 ... 30V DC) and Micro USB (internal)
- Mounting: M8 stud bolt
The PCE-313 A Thermometer measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313 A Thermometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Thermometer to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition. The meter comes manufacturer calibrated (ISO or as an option).
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
PCE-VD 3-ICA is a condition monitoring vibration meter that measures 3-axis shock/vibration via a built-in accelerometer sensor. This condition monitoring vibration meter records 3-axis acceleration (X, Y, Z) vibration measurement data for Fast Fourier Transform (FFT) waveform analysis. The condition monitoring vibration meter connects to your PC via a USB port for configuration and for quick and easy data transfer.
- Measuring range: ±16 g per axis
- Frequency range: 0 ... 60 Hz
- Recording interval: Adjustable from 1 sec .... 24 hr
- Logs and stores up to 168,042 records
- Includes magnetic bracket with wall-mounting screws
- incl. ISO Calibration Certificate
The condition monitoring vibration meter is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this vibration meter, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement.