Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
- Sensor for pipe diameters DN 50 ... 700 / 57 ... 720 mm, DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO-Calibration Certificate
Portable Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Climate Meter PCE-THA 10-ICA incl. ISO Calibration Certificate
US$ 420.00
ex. VAT, ex. delivery costs
ISO Calibration

The climate meter PCE-THA 10 is easy to operate with one hand thanks to its compact size, the new structure and integrated impeller. In addition to the wind speed, the climate meter measures the temperature, humidity, dew point, the wet bulb temperature and the air volume. Average wind speed values can be determined with the climate meter from the 20 preset points.


- Temperature measuring range: -15 ... 50°C / 5 ... 122°F
- Humidity range: 5 ... 95% RH
- Air speed: 0.4 ... 35 m / s
- Air flow: 0 ... 9.999 m3 / s
- Incl. ISO Calibration Certificate

Data Logging Instrument PCE-830-3-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate

Outdoor Construction Noise Meter Kit PCE-432-EKIT-ICA incl ISO Calibration Cert.
US$ 6,917.00
ex. VAT, ex. delivery costs
ISO Calibration

The Class 1 outdoor construction noise meter kit PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor construction noise meter kit is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.

 

- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
Incl. ISO calibration certificate

Portable Ultrasonic Flow Meter PCE-TDS 200+ S-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- Sensor for pipe diameter DN 15 ... 100 / 20 ... 108 mm
- Sensor dimensions: 91 x 52 x 44 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Gloss Meter PCE-IGM 100-ICA incl. ISO calibration certificate
US$ 3,361.00
ex. VAT, ex. delivery costs
ISO Calibration

A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.


- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate

Moisture Meter PCE-MA 60XT-ICA incl. ISO calibration certificate
US$ 3,405.00
ex. VAT, ex. delivery costs
The precision moisture meter enables moisture determinations with a resolution of 0.001 %. The operation of this moisture meter is very simple. Set the drying temperature, place the sample and start drying.

- Weighing range: 60 g
- Readability: 0.1 mg = 0.0001 g / 0.001%
- Drying temperature up to 160°C
- Live graph of moisture content
- Display: Moisture content % / Dry content % / ATRO % / Weight
- Product database for drying parameters
- RS232 / USB interface
- Storage as TXT file directly on USB stick possible
incl. ISO calibration certificate

- Attention to the power supply when ordering!
HVAC Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
US$ 3,419.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.


- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate

NDT Test Instruments PCE-2900-ICA incl. ISO Calibration Certificate
US$ 2,635.00
ex. VAT, ex. delivery costs
ISO Calibration

The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials. The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore. The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle. 

- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS 
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate

Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Material Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The material thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the material thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Climate Meter PCE-HT 420IoT
US$ 501.00
ex. VAT, ex. delivery costs
The climate meter records humidity and air temperature and stores it internally. This compact and robust climate meter in mini format and with a large memory (up to a maximum of 32,000 values ​​/ 16,000 values ​​per parameter) is mainly used for long-term registration (refrigerated counters in department stores, refrigerated transport, warehouses, PC climate control rooms).

- Temperature: -40 ... 70 °C / -40 ... 158 °F
- Humidity: 0 ... 100%
- Dew point calculation (accuracy ± 2°C / 3.6 °F)
- Operating temperature: -40 ... 80 °C / -40 ... 176 °F, max. 80% rH
- Datalogger for temperature and humidity
- LCD display
- E-mail when value is exceeded
- Ethernet with MQTT function
- Power supply or PoE (selectable)
Class 1 SPL Meter PCE-432-SC 09-ICA with Calibrator incl. ISO Certificate
US$ 3,770.00
ex. VAT, ex. delivery costs
ISO Calibration
The Class 1 SPL Meter meets all requirements for noise measurement and frequency analysis. In addition to the sound measurement function, the SPL Meter is equipped with a GPS receiver. The GPS function allows the user to assign the measured values ​​to an exact position.

- Accuracy class 1
- GPS function
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Class 1 sound calibrator
- Incl. ISO Calibration Certificate (for sound calibrator)
NDT Tester - Thickness Meter PCE-TG 150 HT-ICA incl. ISO Calibration Certificate
US$ 1,413.00
ex. VAT, ex. delivery costs
ISO Calibration
The NDT tester - thickness meter can measure material thicknesses up to 300 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the NDT tester - thickness meter.

- Measuring range: 1.20 ... 300.0 mm  / 0.04 ... 11.81"
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 1500 measured values
- Calibration reference on housing
- High temperature probe: -10 ... 350 °C / 14 ...  662 °F
- incl. ISO Calibration Certificate
Class 1 Noise Meter PCE-432-SC 09-ICA with Calibrator incl. ISO Certificate
US$ 3,770.00
ex. VAT, ex. delivery costs
ISO Calibration
The Class 1 Noise Meter meets all requirements for noise measurement and frequency analysis. In addition to the sound measurement function, the Noise Meter is equipped with a GPS receiver. The GPS function allows the user to assign the measured values ​​to an exact position.

- Accuracy class 1
- GPS function
- A, B, C & Z frequency weighting
- Fast, Slow, Impulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Class 1 sound calibrator
- Incl. ISO Calibration Certificate (for sound calibrator)
Climate Meter PCE-EMD 10
US$ 1,043.00
ex. VAT, ex. delivery costs
The climate meter can be connected to up to four external temperature and humidity modules. The temperature measuring range for the climate meter sensors is 32.0 ... 122.0 °F and the humidity measuring range is 0.0 ... 99.9% RH.

- Temperature measuring range: 32.0… 122.0 °F
- Humidity measuring range: 0.0 ... 99.9% RH
- Connection of up to four external sensors
- Analog 4 ... 20-mA input signal
- Wall mounting
Climate Meter PCE-THD 50-ICA incl. ISO Calibration Certificate
US$ 376.00
ex. VAT, ex. delivery costs
ISO Calibration
The climate meter is the ideal measuring device to check the climatic conditions in, for example, warehouses, production halls or greenhouses. The climate meter can measure the ambient temperature and humidity.

- Air temperature: -20 ... 60 °C / -4 ... 140 °F
- Humidity: 0 … 100% RH
- Wet bulb temperature, dew point
- Data memory for 32,000 readings
- Type K thermocouple
- incl. ISO Calibration Certificate