The Electromagnetic Radiation Detector is used in the laboratory and quality assurance to measure the strength of magnetic fields. The Electromagnetic Radiation Detector is delivered with two different sensors. A magnetic field sensor is available for general measurements in the Gauss and milli-Tesla range, as well as a precision sensor for measurements in the milli-Gauss and micro-Tesla range.
- Tabletop device with 2 sensors
General Probe Range: 0-3000 milli-Tesla (0-30,000 Gauss)
Precision Probe Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
- For static and changing magnetic fields
- Highly accurate Transverse Hall sensor
- Different units selectable (mG / µT)
- Data storage on SD memory card
PCE-FD 20 is a material thickness meter with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency material thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
PCE-FD 20 is a portable Wall Thickness Meter or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based Wall Thickness Meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
The humidity detector is an oven-drying absolute moisture meter for weighing and heating material samples to determine moisture content. The heating chamber warms up to 199 °C / 390 °F with the use of halogen lamps. Drying of the sample to be weighed takes place within the chamber of the humidity detector and the moisture content is subsequently calculated from the difference between the initial and final weight.
- Testing or weighing capacity: 200 g / 7.05 oz
- Readability: 10 mg / 0.01 g / 0.1%
- Adjustable drying temperature and time
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
PCE-WM1-ICA is a multi-function handheld humidity detector used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³
- incl. ISO Calibration Certificate
The humidity detector is an absolute moisture meter or halogen moisture analyzer that functions on the gravimetric or loss on drying (LOD) principle. The humidity detector uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the humidity detector can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.01 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.1 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
The Electromagnetic Radiation Detector is used in the laboratory and quality assurance to measure the strength of magnetic fields. The Electromagnetic Radiation Detector is delivered with two different sensors. A magnetic field sensor is available for general measurements in the Gauss and milli-Tesla range, as well as a precision sensor for measurements in the milli-Gauss and micro-Tesla range.
- Tabletop device with 2 sensors
General Probe Range: 0-3000 milli-Tesla (0-30,000 Gauss)
Precision Probe Range: 0-300 micro-Tesla (0-3000 milli-Gauss)
- For static and changing magnetic fields
- Highly accurate Transverse Hall sensor
- Different units selectable (mG / µT)
- Data storage on SD memory card
- Incl. ISO calibration certificateThe PCE-VA 20 is a versatile humidity detector for determining environmental conditions such as wind, temperature and humidity. It is additionally used to test heating, ventilation and air conditioning / cooling (HVAC) systems. This triple thermometer-hygrometer-anemometer device has a 10 cm / 3.9" Ø fan impeller and a clear backlit LCD. Available functions include display hold, average / maximum / minimum value, auto shutdown, low-battery warning, and metric / imperial choice.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±
(3% of measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
- Incl. ISO Calibration Certificate
PCE-FD 20 is a portable ultrasonic tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s