PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic HVAC meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
A gloss meter is a tester for determining surface gloss. Thereby, with the glossmeter, spectral reflections of a light beam that hits the surface, are measured. The touch screen allows for easy navigation.
- Measuring geometries: 20° / 60° / 85°
- Measuring range: 20°: 0 ... 1000 GU / 60°: 0 ... 1000 GU / 85°: 0 ... 160 GU
- Standards: ISO 2813 / GB/T 9754 / ASTM D 523 / ASTM D 2457
- Light source: D65
- Wave length: 400-700 nm
- Incl. ISO calibration certificate
With the air humidity meter it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The air humidity meter offers features such as average value, maximum, minimum, and hold functions at a reasonable price.
- Internal probe
- Temperature: -20°C ... 60°C / -4 ... 140°F
- Relative humidity: 10 ... 90% r.H.
- Temperature of global: -22°C ... 60°C / -8 ... 140°F
- Humidity: -68°C ... 60°C / -90 ... 140°F
- Dew point temperature: depending on the sensor
- External probe
- Temperature: -50° C ... 500° C / -58 ... 932°F
- incl. ISO Calibration Certificate
The environmental tester PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The environmental tester is equipped with an octave band frequency filter. Optionally, the environmental tester can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with an environmental meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The HVAC meter is a portable handheld Clamp Meter used for the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This handy HVAC meter not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.
- True RMS measurement for ACA, ACV
- True power: W, KW, MW
- VA, KVA, MVA, VAR, KVAR, MVAR
- PF (power factor), phase angle (Φ)
- KWH, KVAH, KVARH, PFH
- Voltage measurement range: 10 ... 600 ACV
- Current measurement range: 0.2 ... 1200 ACA
- Real-time current, voltage and power consumption measurement
- Built-in data recorder with adjustable sample rate: 2 ... 7,200 sec.
- Incl. ISO Calibration Certificate
The hardness tester PCE-2900 has been developed for hardness measurements on metallic materials.
The hardness tester PCE-2900 measures the material hardness in Vickers, Brinell, Rockwell, Leeb and Shore.
The hardness tester PCE-2900 measures the hardness according to the Leeb rebound principle.
- Measurement according to Leeb Rebound method
- Measurement units: HLD, HRA, HRB, HRC, HB, HV, HS
- Measurement ranges: 170-960 HLD, 59.1-88 HRA, 3.5-101.7 HRB, 17.9-69.5 HRC, 19-683 HB, 80-1042 HV, 30.6-102.6 HS
- Accuracy: ± 0.5%, Repeatability: ± 0.6%
- Impactor: Type D
- USB and WiFi for data transmission
- Incl. ISO Calibration Certificate
PCE-432-ICA is a class 1 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-430 is a class 1 data-logging noise dose meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy class 1 data-logging noise dose meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- Includes ISO calibration certificate
Without a doubt, the main advantage of this handheld cup vane air velocity meter is that it doesn't need to be held exactly in the direction of the wind. Air velocity meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air velocity meter, wind direction will not influence the measurement.
- 0.9 to 35.0 m/s
- 2.5 to 126.0 km/h
- 1.4 to 68.0 knots
- 1.6 to 78.2 miles/h