The Multifunction Air Flow Meter PCE-THA 10 is easy to operate with one hand thanks to its compact size, the new structure and integrated impeller. In addition to the wind speed, the air flow meter measures the temperature, humidity, dew point, the wet bulb temperature and the air volume. Average wind speed values can be determined with the air flow meter from the 20 preset points.
- Temperature measuring range: -15 ... 50°C / 5 ... 122°F
- Humidity range: 5 ... 95% RH
- Air speed: 0.4 ... 35 m / s
- Air flow: 0 ... 9.999 m3 / s
- Incl. ISO Calibration Certificate
PCE-AS1 is an air sampling meter used to assess microbiological pollution and monitor hygiene. Designed for use in hospitals, clean rooms, food, beverage, cosmetics, and pharmaceutical production facilities. The PCE-AS1 air sampler meets the latest requirements for devices used for airborne microbial analysis of bacterial and fungal counts. Rate is 100 lpm or 3.53 cfm with 300 micropores. **Optional ISO lab calibration listed under accessories**
- Accommodates manual adjustment of air volumes from 10 to 6000 liters
- Offers data storage for up to 99 parameters / 2000 measurement records
- Aids in compliance with HACCP, FDA FMSA, USP 797 and ISO 14698-1
- Runs off a rechargeable battery or AC power
- Supports standard Petri dishes of 90 mm / 3.5 in
- Software free as QR image for IOS / Android
The PCE-830 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-HVAC 2 is a Flow Meter that measures air velocities up to 80 m/s. It is possible to measure air speed, air pressure, air flow, differential pressure and ambient temperature with this mobile Flow Meter. Readings can be taken in narrow pipes and other restricted spaces because the pitot tube can be inserted in very small gaps.-
- Measures air velocities up to 80 m/s / 262 ft/s, 2.24 ... 178.66 MPH
- Zero, minimum, maximum, average, record and hold functions
- Stores to memory up to 99 measurement values per parameter
- Includes ISO calibration certificate
The PCE-830-3 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The PCE-830-3 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The Multifunction Air Flow Meter PCE-THA 10 is easy to operate with one hand thanks to its compact size, the new structure and integrated impeller. In addition to the wind speed, the air flow meter measures the temperature, humidity, dew point, the wet bulb temperature and the air volume. Average wind speed values can be determined with the air flow meter from the 20 preset points.
- Temperature measuring range: -15 ... 50°C / 5 ... 122°F
- Humidity range: 5 ... 95% RH
- Air speed: 0.4 ... 35 m / s
- Air flow: 0 ... 9.999 m3 / s
- Incl. ISO Calibration Certificate
The 4-channel PCE-VM 5000-ICA Vibration Meter performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The class 2 outdoor sound level meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc.
The outdoor sound level meter is equipped with an octave band frequency filter.
Optionally, the outdoor sound level meter can be upgraded with a 1/3 octave band filter.
The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate