The PCE-830-3 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The laboratory balance PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the laboratory balance dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
PCE-MA 110 is a halogen moisture test instrument or analyzer that functions on the gravimetric or loss on drying (LOD) principle. The moisture analyzer uses the halogen method to dry the material sample. Moisture content is calculated based on the weight difference before and after the drying procedure. Calibration of the moisture analyzer can be performed at any time using the automatic calibration function and the included 100 g weight.
- Weighing range: 0.1 g ... 110 g / 0.0035 ... 3.88 oz
- Weighing resolution or readability: 0.01 g / 10 mg
- Moisture content measuring range: 0 ... 100%
- Moisture content resolution or readability: 0.1%
- Adjustable drying time and temperature
- Memory stores up to 16 drying profiles
The precision balance PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the precision balance dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm diameter / 2.2 in
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The analytical balance PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the analytical balance dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
The Benchtop Scale PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the Benchtop Scale dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
The LAB Scale PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the LAB Scale dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
The Tabletop Scale PCE-MA 100-ICA allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the Tabletop Scale dries the material to be weighed, and then calculates the moisture content from the weight difference.
- Testing or weighing capacity: 110 g / 3.88 oz
- Readability: 1 mg / 0.001 g / 0.01 %
- Adjustable drying temperature and time
- incl. ISO Calibration Certificate
The moisture analyzer is a sensor for measuring moisture of sand and liquids consisting of a central probe surrounded by four other probes. The probes and sensor housing are made of stainless steel AISI 321. Our moisture analyzer is ideally suited for installation in tanks with liquid materials such as fuel oil, sludge from cement production, and fuels (CWF).
- Readability mass fraction of water: 0 ... 100%
- Moisture measurement range: ± 0.1 ... 10% (water mass fraction))
- Maximum permissible absolute error moisture measurement: Varies by material, lab test required
- Temperature range: +5 ... +80 °C