The Data Logger with microprocessor is a high precision 1-channel temperature gauge. The Data Logger with microprocessor is ideal for use with various Pt100 sensors. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- 1 channel temperature recorder
- Automatic shutdown
- High accuracy of ± 2% r.H.
- Sampling rate of 2 / sec
- Memory size: 5,000 values
The Temperature Data Logger with microprocessor is a high precision 1-channel temperature gauge. The Temperature Data Logger with microprocessor is ideal for use with various Pt100 sensors. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- 1 channel temperature recorder
- Automatic shutdown
- High accuracy of ± 2% r.H.
- Sampling rate of 2 / sec
- Memory size: 5,000 values
Data logger to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of airflow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.
The radioactivity data logger measures α-, β-, γ- and X-rays and offers a high measurement accuracy and convenient design. Using the integrated Bluetooth interface in the radioactivity data logger, the measured values can be sent in real time to a PC and analyzed with the included PC software.
- α-, β-, γ- and X-rays
- Bluetooth interface
- Internal memory
- PC software included
PCE-WB 20SD is a multifunction wet bulb temperature data logger used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data recording device is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.
This Data Logger meter is very economical. With this Data Logger meter you can measure wind speed and air temperature. These test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Speed measurement up to 45 m/s or 100 mph
- Wind speed: 0.01 m/s, accuracy ±3% ±0.1
- Air temperature: 0.2°C / 32.4°F, accuracy ±1°C / 33.8°F
- Air flow: 0.001 to 100, accuracy calculated from the wind speed and surface
The Temperature Data Logger measures relative humidity and temperature and can be used in the air-conditioning sector. The Temperature Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Temperature Data Logger to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition. The logging meter comes manufacturer calibrated (ISO calibration certificate as an option).
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
The PCE-313 S Data Logger has been designed for professional use in fields such as the air-conditioning sector. The PCE-313 S Data Logger determines both relative humidity and ambient temperature. The PCE-313 S Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. These logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F
The Temperature Data Logger has been designed for professional use in fields such as the air-conditioning sector. The Temperature Data Logger determines both relative humidity and ambient temperature. The Temperature Data Logger can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. These logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.54 ... 120°F