HVAC Meter PCE-320-ICA incl. ISO Calibration Certificate
US$ 697.00
ex. VAT, ex. delivery costs
ISO Calibration

With the HVAC meter it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The HVAC meter offers features such as average value, maximum, minimum, and hold functions at a reasonable price.


- Internal probe

- Temperature: -20°C ... 60°C / -4 ... 140°F
- Relative humidity: 10 ... 90% r.H.
- Temperature of global: -22°C ... 60°C / -8 ... 140°F
- Humidity: -68°C ... 60°C / -90 ... 140°F
- Dew point temperature: depending on the sensor

- External probe
- Temperature: -50° C ... 500° C / -58 ... 932°F

- incl. ISO Calibration Certificate 

 

Outdoor Noise Dose Meter PCE-428-EKIT-ICA incl. ISO Calibration Certificate
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The class 2 outdoor noise dose meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor noise dose meter is equipped with an octave band frequency filter. Optionally, the outdoor noise dose meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a noise dose meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

Outdoor Aircraft Noise Meter PCE-428-EKIT-ICA incl. ISO Calibration Certificate
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The class 2 outdoor aircraft noise meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor aircraft noise meter is equipped with an octave band frequency filter. Optionally, the outdoor aircraft noise meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with an aircraft noise meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

Outdoor Decibel Meter PCE-428-EKIT-ICA incl. ISO Calibration Certificate
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The class 2 outdoor decibel meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor decibel meter is equipped with an octave band frequency filter. Optionally, the outdoor decibel meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a decibel meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

Outdoor SPL Meter PCE-428-EKIT-ICA incl. ISO Calibration Certificate
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The class 2 outdoor SPL meter PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor SPL meter is equipped with an octave band frequency filter. Optionally, the outdoor SPL meter can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

Environmental Meter PCE-HVAC 3-ICA Incl. ISO Calibration Certificate
US$ 457.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-HVAC 3 is a environmental meter or diagnostic measuring device used for indoor climate and environmental monitoring. In addition to measuring relative humidity and ambient room / dry-bulb temperature, the environmental meter calculates dew-point and wet-bulb temperatures in degrees Celsius (°C) and Fahrenheit (°F). Thus, heating, ventilation and air conditioning (HVAC) installations and HVAC system performance assessments are key applications of the PCE-HVAC 3 environmental meter.


- Relative humidity measuring range: 0 ... 100% RH
- Ambient / dew-point temp. range: -30 ... 100°C / -22 ... 212°F
- Wet-bulb temp. range: 0 ... 80°C / 32 ... 176°F
- Incl. ISO calibration certificate

HVAC Meter PCE-VE 270HR
US$ 4,290.00
ex. VAT, ex. delivery costs
The PCE-VE 270HR HVAC Meter gives you new, visual insights into the interior of motors and systems. The HVAC meter is the ideal tool for maintenance and repair in workshops or industrial companies. Optical analysis with a videoscope HVAC meter has never been so easy.

- Cable length:  2 m, 6.56 ft
- Cable diameter:  2.8 mm, 0.11 inch
- 0° viewing angle
- Camera resolution / image sensor:  400 x 400 Px
- Cable type: flexible
- Video output: HDMI
- LED light

 

HVAC Meter PCE-VT 1100S-ICA incl. ISO Calibration Certificate
US$ 615.00
ex. VAT, ex. delivery costs
ISO Calibration

 The HVAC meter is suitable for relative measurements on various machines. With the 45 mm long needle probe, you can access hard-to-reach places in machines and motors. For this reason, this HVAC meter is used for rapid measurement of imbalance and for checking bearing and gear conditions.


 

- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Portable and battery operated
- Needle probe: 45mm / 1.77"
- incl. ISO Calibration Certificate

HVAC Meter PCE-VT 1100-ICA incl. ISO Calibration Certificate
US$ 615.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC Meter is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this HVAC Meter, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement.

 

- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units
- Holds the reading after each measurement
- Easy to handle and battery operated
- Standard probe: 10mm
- incl. ISO Calibration Certificate

HVAC Meter PCE-VT 1100M-ICA incl. ISO Calibration Certificate
US$ 647.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC meter is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this HVAC meter, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement. 

- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units only
- Holds the reading after each measurement
- Easy to handle and battery operated
- Standard probe: 10 mm
- including magnetic sensor
- incl. ISO Calibration Certificate

Flow Meter PCE-TDS 100HMHS-ICA incl. ISO Calibration Certificate
US$ 3,419.00
ex. VAT, ex. delivery costs
ISO Calibration
The flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
                      20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
Environmental Tester PCE-428-EKIT-ICA incl. ISO Calibration Certificate
US$ 5,478.00
ex. VAT, ex. delivery costs
ISO Calibration

The environmental tester PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The environmental tester is equipped with an octave band frequency filter. Optionally, the environmental tester can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with an environmental meter over a long period of time, even in the rain.

 

- Accuracy class 2 
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate

Power Analyzer PCE-830-2-ICA incl. ISO Calibration Certificate
US$ 4,192.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate

Portable Ultrasonic Flow Meter PCE-TDS 200+ S-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Portable Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the
Portable Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- Sensor for pipe diameter DN 15 ... 100 / 20 ... 108 mm
- Sensor dimensions: 91 x 52 x 44 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
- Sensor for pipe diameters DN 15 ... 100 / 20 ... 108 mm, DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO Calibration Certificate
Ultrasonic Flow Meter PCE-TDS 200+ SL-ICA incl. ISO Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The ultrasonic flow meter has a measuring range of ±32 m/s. To perform flow measurement with the
ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0.001 m/s
- incl. 4 sensors
Pipe size:
  DN
 15 ... 100 / 20 ... 108 mm,
  DN 300 ... 6000 mm
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- measuring parameters: Flow velocity,
  volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 10 million measuring points
- LiPo battery
- incl. ISO Calibration Certificate
Power Analyzer PCE-830-1-ICA incl. ISO Calibration Certificate
US$ 3,788.00
ex. VAT, ex. delivery costs
ISO Calibration

The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.


- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate

Clamp-on Ultrasonic Flow Meter PCE-TDS 200+ ML-ICA incl. ISO-Calibration Certificate
US$ 5,222.00
ex. VAT, ex. delivery costs
ISO Calibration
The Clamp-on Ultrasonic Flow Meter has a measuring range of ±32 m/s. To perform flow measurement with the Clamp-on Ultrasonic Flow Meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications.

- Measuring range: ±32 m/s
- Resolution: 0,001 m/s
- incl. sensor set
- Sensor for pipe diameters DN 50 ... 700 / 57 ... 720 mm, DN 300 ... 6000 mm
- Temperature resistance: -30 ... 160 °C
- Temperature measurement up to 1800 °C
- for different media
- for different pipe materials
- Measuring parameters: flow velocity, volume flow, volume
  temperature, heat output and heat quantity
- Interface: USB
- Cost display
- Data logger: 32 GB memory capacity (10 million measuring points)
- LiPo battery
- incl. ISO-Calibration Certificate