The 4-channel PCE-VM 5000-ICA Vibration Recorder performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The Class 1 outdoor decibel meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor decibel meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor SPL meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor SPL meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor sound level meter PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor sound level meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor SPL meter PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor SPL meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor decibel meter PCE-432-EKIT can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The outdoor decibel meter is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
PCE-430 is a class 1 data-logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy class 1 data-logging decibel meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- Includes ISO calibration certificate
PCE-430 is a class 1 data-logging SPL meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy class 1 data-logging SPL meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- Includes ISO calibration certificate