Due to its compact design, the PCE-2550-ICA hardness tester is easy to use for incoming and outgoing inspections. Due to the adjustable hardness scales, the hardness tester is very versatile.
- Measuring ranges: 170 ... 960 HLD
- Measurement direction: 360°
- Impact device: Type D
- Measurement units: HL, HB, HRB, HRC, HRA, HV, HS
- Internal measurement memory
- incl. ISO Calibration Certificate
- Measures Ra, Rz, Rq and Rt in Metric (µm) and Imperial (µinch)
- Ra, Rq: 0.005 ... 16.00 μm / 0.197µinch... 629.921 µinch measurement range
- Rz, Rt: 0.002 ... 200.0 μm / 0.079µinch... 7874.016 µinch measurement range
- Induction method with Diamond sensor
- Accuracy < ± 10% and Repeatability < 6%
- Saves up to 20 Data points
- Micro-USB interface
- Built-in rechargeable li-ion battery
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000-ICA Vibration Meter performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000-ICA Vibration Analyzer performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
Due to its compact design, the PCE-2550-ICA material tester is easy to use for incoming and outgoing inspections. Due to the adjustable hardness scales, the material tester is very versatile.
- Measuring ranges: 170 ... 960 HLD
- Measurement direction: 360°
- Impact device: Type D
- Measurement units: HL, HB, HRB, HRC, HRA, HV, HS
- Internal measurement memory
- incl. ISO Calibration Certificate
The Class 1 outdoor sound level meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor sound level meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor decibel meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor decibel meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The Class 1 outdoor SPL meter PCE-430-EKIT-ICA with integrated data logger meets all requirements for noise measurement and frequency analysis. This integrated precision pulse outdoor SPL meter kit follows all valid standards and guidelines, and is designed for use outdoors in all weather. Typical applications are the measurement of workplace noise, compliance, environmental noise detection, selection of hearing protector selection, selection of appropriate noise abatement measures and noise exposure estimation.
- Accuracy class 1
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The HVAC meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The HVAC meter works according to the transit time difference method. The measuring principle of the HVAC meter is quite simple.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe sizes: 50 … 720 mm (approx. 1.9 … 28")
20 …108 mm (approx. 0.8 … 4.2")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-HM and TDS-HS on rails
- Incl. ISO Calibration Certificate
Due to its compact design, the PCE-2550-ICA metal hardness tester is easy to use for incoming and outgoing inspections. Due to the adjustable hardness scales, the metal hardness tester is very versatile.
- Measuring ranges: 170 ... 960 HLD
- Measurement direction: 360°
- Impact device: Type D
- Measurement units: HL, HB, HRB, HRC, HRA, HV, HS
- Internal measurement memory
- incl. ISO Calibration Certificate
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Clamp Meter also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000-ICA Vibration Recorder performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The PCE-830-3 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate