The PCE-CT26 coating thickness gauge or meter is used for quickly detecting the coating thickness of paint on magnetic metals, such as iron in the automotive sector. One typical use is in detecting damage to car bodies to establish if the car has been in an accident and the resulting value of the car in the used car market.
- Measurement range: 0 ... 2000 µm / 0 ... 79 mils
- Resolution: 0.1 µm (0 to 99.9 µm) / 1 µm ( >100 µm)
- Accuracy: ±1 to 3% or 2.5 µm
- Display: 4 digit LCD, 10 mm in height
The PCE-779N-ICA Surface Testing - Temperature Meter measures temperatures quickly and without contact. The temperature meter can be used for almost all surfaces. The emissivity of the temperature meter is adjustable over the range of 0.1 ... 1.0. The temperature meter has various measurement functions such as max, min and average measurement.
- OLED-Display
- Measuring range: -60 ... 760°C / -76 ... 1400°F
- Additional thermocouple measurement -64 ... 1400°C / -83.2 ... 2552°F
- Dual Laser
- Resolution: 0.1°C / 0.18°F at -83.2 ... 999.9°C (-117.8 ... 1831.8°F), otherwise 1°C / 1.8°F
- incl. ISO Calibration Certificate
The surface thickness measuring device is used for the quick and precise detection of layer thicknesses on metals. In comparison to many other thickness meters, this surface thickness measuring device does not have to differentiate between ferrous and non-ferrous metal.
With the PCE-890U Surface Testing - Temperature Meter, measurements of surface temperatures can be carried out quickly and easily. Since the temperature meter uses infrared radiation for temperature measurement, no direct contact with the measuring object is required. The temperature meter makes it easy to measure objects from a distance that are difficult to access.
- Measuring range: -50 ... 1150°C / -58 ... 2102°F
- Accuracy: ± 1.5% ± 2°C / 3.6°F (0 ... 500°C / 32 ... 932°F)
- Resolution: 0.1°C / 0.18°F (<1000°C / 1832°F)
- Emission level: 0.1 ... 1
With the Surface Testing - Infrared Thermometer PCE-IR 50, surface temperatures can measured quickly and easily. The measuring range of the Infrared Thermometer is 0 ... 500 °C / 32 ... 932 °F. The measured temperature is output as a 4 ... 20-mA standard signal which means that the Infrared Thermometer can be easily integrated into different monitoring systems, including those in different production processes or food storage as well as the monitoring of electronic systems.
- Measurement range: 0 ... 500 °C / 32 ... 932 °F
- Accuracy: ± 1.5 °C or ± 1 %
- Optical resolution: 15:1
- Output signal: 4 ... 20-mA standard signal
- For fixed installation (mounting bracket incl.)
The PCE-T390 temperature meter is a digital device with four input channels for type K and type J temperature sensors and two input channels for PT100 temperature sensors. The PCE-T390 temperature meter has a SD card slot (from 1 ... 16 GB) for storing the measured data. The data is stored in xls format on the SD card of the temperature meter so that no additional software is needed for further analysis.
- 4 input channels for type-K, J temperature sensors
- 2 input channels for Pt100 temperature sensors
- 2 x type-K TF-500 temperature sensors are included in the package
- SD card memory (1 ... 16 GB)