The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 1) 20 A ... 1200 A AC or (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
ex. VAT, ex. delivery costs
PCE-PCO 2 is a portable handheld data logger used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this data logger also measures air temperature, dew point and relative humidity.
- PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
- Particle sizes (in micrometers): 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Temp. measuring range: 0 ... +50 °C / +32 ... +122 °F
- Humidity measuring range: 0 ... 100 % RH
- Built-in camera for image and video recording
- Free software download on PCE Software web page
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
The 4-channel PCE-VM 5000 Data Logging Instrument performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested. These Data Logging Instrument are manufacturer calibrated. An ISO calibration certificate is an option.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
ex. VAT, ex. delivery costs
The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Voltage range: 50.0 V ... 600.0 V True RMS value
- Current range: 3.0 A ... 999.9 A True RMS value
- Includes clamps, clips, leads, PC software and data cable
- Data logger of 10,000,000 records at 5/10/30/60/120 second interval options
- For measurement in real time and over an extended time period up to 578 days @ 5 second sample rate
ex. VAT, ex. delivery costs
The PCE-360 is a HVAC Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Voltage range: 50.0 V ... 600.0 V True RMS value
- Current range: 3.0 A ... 999.9 A True RMS value
- Includes clamps, clips, leads, PC software and data cable
- Data logger of 10,000,000 records at 5/10/30/60/120 second interval options
- For measurement in real time and over an extended time period up to 578 days @ 5 second sample rate
- incl. ISO Calibration Certificate
ex. VAT, ex. delivery costs
PCE-PCO 1 is a handheld data logger for measuring the concentration of particles in the air. The PCE-PCO 1 data logger:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust, 80 MB internal memory
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
The 4-channel PCE-VM 5000-ICA Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
The Sound Level Data Logger PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- GPS receiver for location determination
- Adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
ex. VAT, ex. delivery costs
The PCE-HT110 Humidity / Temperature Data Logger or Humidity Detector precisely measures air temperature and relative humidity. This accurate and reliable device shows the current measurements on the large LCD display and saves the measurement data directly to an SD card (included). The PCE-HT110 is equipped with two channels, accommodates an SD card memory of up to 16 GB, offers an adjustable measurement rate / sampling interval, and includes a wall mount, making the device ideal for logging data over an extended period of time.
- Measurement ranges: 0 … 50°C / 32 ... 122°F, 10 ... 90% RH
- Resolution: 0.1°C / 0.18°F, 0.1% RH
- Data format: .XLS (compatible with Microsoft Excel)
- Set = Quantity of 5 x units
ex. VAT, ex. delivery costs
The PCE-830-2 Three Phase Power Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three Phase Power Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
ex. VAT, ex. delivery costs
The PCE-830 Power Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Data Logger also measures such parameters as voltage, current, frequency, harmonics and power as well as indicting, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm diameter / 2.2 in
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
ex. VAT, ex. delivery costs
The pH meter PCE-PHD 1-PH is for checking the water quality. The portable pH meter is very well suited for controlling the water parameter pH.
- pH-value: 0.00 ... 14.00 pH
- Real-time data logger
- SD card memory (16 GB max.)
- Adjustable measuring rate
- Automatic calibration
- pH electrode and temperature sensor included
ex. VAT, ex. delivery costs
PCE-430 is a sound level data logger that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
- Measuring range: 22 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
The PCE-830 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logger also measures such parameters as voltage, current, frequency, hrmonics and power as well as indicting, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
ex. VAT, ex. delivery costs
The PCE-830 Three Phase Power Data Logger Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three Phase Power Data Logger Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
ex. VAT, ex. delivery costs
The PCE-830-3 Three Phase Power Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Three Phase Power Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)