The hay contact thermometer PCE-HMM is a professional device to designed to determine moisture and temperature of pressed hay and straw. The hay contact thermometer features a sensor made of stainless steel, which can be purchased in four different lengths, while the wooden handle has an ergonomic design. The hay contact thermometer proves to be extremely robust, designed to withstand applications for many years.
- Measuring lance: 50 cm
- Measuring range moisture: 9 ... 50%
- Measuring range temperature: -10 ... 100°C / 14 ... 212°F
- Resolution of display: 0.1%
- Accuracy: 0.8%
The accelerometer is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this accelerometer, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement.
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units only
- Holds the reading after each measurement
- Easy to handle and battery operated
- Standard probe: 10 mm
- including magnetic sensor
- incl. ISO Calibration Certificate
The condition monitoring vibration meter is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this condition monitoring vibration meter, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement.
- Frequency range: 10 Hz ... 1 kHz
- Measures speed, distance, acceleration in metric units only
- Holds the reading after each measurement
- Easy to handle and battery operated
- Standard probe: 10 mm
- including magnetic sensor
- incl. ISO Calibration Certificate
The PCE-VA 20 is a versatile Dew Point Thermometer for determining environmental conditions such as wind, temperature and humidity. It is additionally used to test heating, ventilation and air conditioning / cooling (HVAC) systems. This triple thermometer-hygrometer-anemometer device has a 10 cm / 3.9" Ø fan impeller and a clear backlit LCD. Available functions include display hold, average / maximum / minimum value, auto shutdown, low-battery warning, and metric / imperial choice.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±
(3% of measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
- Incl. ISO Calibration Certificate
The condition monitoring vibration meter is used as a hand-held measuring device for the individual assessment of vibrations on machines and systems. With the help of this vibration meter, the actual state can easily be determined on site. Thus, corresponding changes can be made directly on site after the measurement.
PCE-VS12 is a vibration meter, analyzer or sensor condition monitoring switch used to measure RMS value, peak value and frequency domain (FFT) of vibration velocity or acceleration piezoelectrically. This IP67-rated vibration monitoring switch features an external USB port, 8-pin female connector 711 and programmable high pass and low pass filters.
- Frequency range (max.): 0.1 Hz ...10 kHz
- Measuring range: Acceleration = 0.1 ... 1000 m/s², Speed =
Frequency-dependent
- Connections: Screw terminals for power supply (5 ... 30V DC) and Micro USB (internal)
- Mounting: M8 stud bolt
PCE-VS12 is a vibration meter, analyzer or sensor condition monitoring switch used to measure RMS value, peak value and frequency domain (FFT) of vibration velocity or acceleration piezoelectrically. This IP67-rated vibration monitoring switch features an external USB port, 8-pin female connector 711 and programmable high pass and low pass filters.
- Frequency range (max.): 0.1 Hz ...10 kHz
- Measuring range: Acceleration = 0.1 ... 1000 m/s², Speed =
Frequency-dependent
- Connections: Screw terminals for power supply (5 ... 30V DC) and Micro USB (internal)
- Mounting: M8 stud bolt
The PCE-VE 200SV1 industrial borescope is a nondestructive inspection camera. Thus, the PCE-VE 200SV1 industrial borescope is the ideal instrument for diagnosing hard-to-reach areas. Thus, the areas of mechanical engineering, sanitary and heating construction, and the entire construction and construction industry are among the main applications of the industrial borescope PCE-VE 200SV1.
- Camera head diameter 9 mm / 0.4 in
- Cable length: 1 m / 3.3 ft
- Interface: Micro USB 2.0
- Memory: Micro SD card
- Front and side view camera
PCE-VA 20-SET is a Dew Point Thermometer with capture hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) systems. This combined hygrometer-anemometer-thermometer possesses a 10 cm / 3.9" diameter fan impeller and a bright backlit LCD. The functions of the air flow device incorporate display hold, mean value, max value, min value, battery-saving auto shutdown, low-battery display, and a choice between metric and imperial units.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3" Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
The PCE-313A condition monitoring thermometer measures relative humidity and temperature and can be used in the air-conditioning sector. The PCE-313A condition monitoring thermometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the condition monitoring thermometer to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the humidity test instrument can be used for long term data acquisition.
- Relative humidity: 5 ... 95% r.H.
- Temperature: 0 ... 50°C / 32 ... 122°F
- Type K: -50 ... 1300°C / -58 ... 2372°F
- Calculated dew point: -25.3 ... 48.9°C / -13.5 ... 120°F
- Wet bulb temperature: -21 ... 50°C / -5.8 ... 122°F
- Memory: SD card (1 ... 16 GB)
- Incl. ISO Calibration Certificate
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- Incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.