HVAC Meter / HVACR Tester PCE-UFM 32CU
US$ 1,703.00
ex. VAT, ex. delivery costs
Our HVAC Meter / HVACR Tester enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 28 and 36 mm. The HVAC Meter / HVACR Tester of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN32 (28 ... 36 mm)
HVAC Meter / HVACR Tester PCE-UFM 32PVC
US$ 1,703.00
ex. VAT, ex. delivery costs
Our HVAC Meter / HVACR Tester enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 35 and 43 mm. The HVAC Meter / HVACR Tester of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN32 (35 ... 43 mm)
HVAC Meter PCE-IVE 330
US$ 1,678.00
ex. VAT, ex. delivery costs

The HVAC meter is used to diagnose and monitor hard-to-reach areas on vehicles, containers, machinery and equipment. Thanks to the 3 m telescopic rod of the HVAC meter, it is also possible to view areas that are difficult to access. Visual monitoring with the HVAC meter is supported by the flexible camera head.


  • Camera length: 320 mm / 12.5"
  • Camera diameter: 23 mm / 0.9"
  • Flexible camera head
  • 8" LCD monitor
  • Memory function

HVAC Meter PCE-VT 3850S
US$ 1,659.00
ex. VAT, ex. delivery costs
The HVAC meter is the ideal companion for checking vibrating parts, machines and systems. With the external vibration sensor on the HVAC meter, the vibration displacement up to 3.9 mm, the vibration velocity up to 399.9 mm/s and the vibration acceleration up to 399.9 m/s² can be determined.

Measuring ranges
  • Acceleration: 0.0 … 399.9 m/s² / 0.0 - 15744 in/s²
  • Velocity: 0.00 … 399.9 mm/s / 0.00 - 15.74 in/s
  • Displacement: 0.000 … 3.9 mm / 0.000 - 0.154 in
  • Automatic ISO 10816-3 evaluation
  • Data logger: 50 memory locations with 43200 measured values each
  • Rechargeable battery
  • Color graphic display
  • Measuring tip with handgrip- incl. headset
HVAC Meter PCE-VT 3800S-ICA incl. ISO Calibration Certificate
US$ 1,639.00
ex. VAT, ex. delivery costs
ISO Calibration

The HVAC meter is the ideal companion for checking vibrating parts, machines and systems. With the external vibration sensor on the HVAC meter, the vibration displacement up to 3.9 mm, the vibration velocity up to 399.9 mm/s and the vibration acceleration up to 399.9 m/s² can be determined.

Measuring ranges

  • Acceleration: 0.0 … 399.9 m/s² / 0.0 - 15744 in/s²
  • Velocity: 0.00 … 399.9 mm/s / 0.00 - 15.74 in/s
  • Displacement: 0.000 … 3.9 mm / 0.000 - 0.154 in
  • Automatic ISO 10816-3 evaluation
  • Data logger: 50 memory locations with 43200 measured values each
  • Rechargeable battery
  • Color graphic display
  • Measuring tip with handgrip
  • incl. ISO Calibration Certificate

HVAC Meter PCE-UFM 15
US$ 1,596.00
ex. VAT, ex. delivery costs
With our fixed installation HVAC meter, you have the capability to measure flow rates from ±0.1 m/s to ±5 m/s. The fixed installation HVAC meter is suitable for small pipes with a diameter of DN15 / 1/2" and various pipe materials such as steel, copper, aluminum, and plastics.

  • Measurement Range: 0.1 … 5 m/s
  • Resolution: 0.001 m/s
  • Accuracy: 2%
  • Pipe Size: DN15 / 1/2"
  • Display Type: OLED
  • Analog Output: 4 … 20mA
HVAC Meter PCE-UFM 25
US$ 1,596.00
ex. VAT, ex. delivery costs
With our fixed installation HVAC meter, you have the capability to measure flow rates from ±0.1 m/s to ±5 m/s. The fixed installation HVAC meter is suitable for small pipes with a diameter of DN25 / 1" and various pipe materials such as steel, copper, aluminum, and plastics.

  • Measurement Range: 0.1 … 5 m/s
  • Resolution: 0.001 m/s
  • Accuracy: 2%
  • Pipe Size: DN25 / 1"
  • Display Type: OLED
  • Analog Output: 4 … 20mA
HVAC Meter PCE-UFM 4
US$ 1,596.00
ex. VAT, ex. delivery costs
With our fixed installation HVAC meter, you have the capability to measure flow rates from ±0.1 m/s to ±5 m/s. The fixed installation HVAC meter is suitable for small pipes with a diameter of DN4 / 1/8" and various pipe materials such as steel, copper, aluminum, and plastics.

  • Measurement Range: 0.1 … 5 m/s
  • Resolution: 0.001 m/s
  • Accuracy: 2%
  • Pipe Size: DN4 / 1/8"
  • Display Type: OLED
  • Analog Output: 4 … 20mA
HVAC Meter PCE-VT 3750S
US$ 1,571.00
ex. VAT, ex. delivery costs
The HVAC meter is ideal for maintenance workers to quickly check vibrating parts, machines and systems. This HVAC meter shows the vibration acceleration, vibration velocity and vibration displacement directly on the display. The measurement unit can be switched between the metric system and imperial units.

Measuring ranges
  • Acceleration: 0.0 - 399.9 m/s² / 0.0 - 15744 in/s²
  • Velocity: 0.00 - 399.99 mm/s / 0.00 - 15.74 in/s
  • Displacement: 0.000 - 3.9 mm / 0.000 - 0.154 in
  • Automatic ISO 10816-3 evaluation
  • Colored graphic display
  • incl. headset