Ultrasonic Tester / Ultrasonic Testing

Ultrasonic Tester / Ultrasonic Testing PCE-UFM 32CU
£ 1,148.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 28 and 36 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN32 (28 ... 36 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 32PVC
£ 1,148.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 35 and 43 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN32 (35 ... 43 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 40CU
£ 1,219.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 35 and 43 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN40 (35 ... 43 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 40PVC
£ 1,219.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 46 and 54 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN40 (46 ... 54 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 50CU
£ 1,321.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 46 and 54 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN50 (46 ... 54 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 50PVC
£ 1,321.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 59 and 67 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN50 (59 ... 67 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 65CU
£ 1,406.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 59 and 67 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN65 (59 ... 67 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 65PVC
£ 1,406.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 72 and 80 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN65 (72 ... 80 mm)
Ultrasonic Tester / Ultrasonic Testing PCE-UFM 80CU
£ 1,546.00
Price excl. VAT &. delivery
Our Ultrasonic Tester / Ultrasonic Testing enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 72 and 80 mm. The Ultrasonic Tester / Ultrasonic Testing of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN80 (72 ... 80 mm)