This Probe Thermometer is suitable for fast, non-contact temperature measurement during maintenance and servicing work, in mechanical and systems engineering, on heating, ventilation and air-conditioning systems, and for checking surfaces in various industrial applications. The Probe Thermometer enables measurements in the range from -50 … 1000°C. It also features a Type K input for contact measurements in the range from -50 … 1370°C.
With a response time of less than 150 ms, the Probe Thermometer enables rapid recording of temperature values. The 20:1 measurement spot ratio allows measurements from greater distances, while the circular laser target guide supports precise alignment with the measuring point. The emissivity can be adjusted from 0.10 … 1.0, allowing it to be adapted to different surfaces. The spectral response range is 8 … 14 µm. MAX, MIN, DIF and AVG functions, as well as upper and lower limit alarms, are available for monitoring measured values.
The Probe Thermometer has a backlit LCD and allows the selection of °C or °F. An automatic data-hold function, automatic switch-off, an over-range indicator and a trigger lock for continuous measurements complete the equipment. Power is supplied by two 1.5V AAA batteries.
With IP54 protection and having passed a drop test from heights of up to 3 m, the Probe Thermometer is suitable for demanding use during maintenance and servicing work. The combination of non-contact infrared measurement and contact measurement with a Type K thermocouple makes the device suitable for versatile temperature measurements in industrial applications.
| Type K temperature | |
| Measuring range | -50 ... 0 °C |
| Resolution | 0,1 °C |
| Accuracy | ±2 °C |
| Type K temperature | |
| Measuring range | 0 ... 1000 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.5% of reading or ±1.5°C (larger value applies) |
| Type K temperature | |
| Measuring range | 1000 ... 1370 °C |
| Resolution | 1 °C |
| Accuracy | ±0.5% of reading or ±1.5°C (larger value applies) |
| Type K temperature | |
| Measuring range | -58 ... +32 °F |
| Resolution | 0,1 °F |
| Accuracy | 3.6°F |
| Type K temperature | |
| Measuring range | 32 ... 1832 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.5% or 3°F (larger value applies) |
| Type K temperature | |
| Measuring range | 1832 ... 2498 °F |
| Resolution | 1 °F |
| Accuracy | ±0.5% or 3°F (larger value applies) |
| Infrared temperature | |
| Measuring range | -50 ... +20 °C |
| Resolution | 0,1 °C |
| Accuracy | ±3.5°C |
| Infrared temperature | |
| Measuring range | 20 ... 300 °C |
| Resolution | 0,1 °C |
| Accuracy | ±1% of reading or ±1.0°C (larger value applies) |
| Infrared temperature | |
| Measuring range | 300 ... 1000 °C |
| Resolution | 0,1 °C |
| Accuracy | ±1.5% f.s. |
| Infrared temperature | |
| Measuring range | -58 ... +68 °F |
| Resolution | 0,1 °F |
| Accuracy | ±6.3°F |
| Infrared temperature | |
| Measuring range | 68 ... 572 °F |
| Resolution | 0,1 °F |
| Accuracy | ±1% of reading or ±1.8°F (larger value applies) |
| Infrared temperature | |
| Measuring range | 572 ... 1832 °F |
| Resolution | 1 °F |
| Accuracy | ±1.5% of full scale |
| General technical data | |
| Measuring functions | MIN, MAX, HOLD, AVG, DIF |
| Display type | LC colour display with backlight |
| Display size | 1,6 Inch |
| Response time | 150 mS |
| Measurement spot | 20:1 |
| Laser | Class 2 <1mW |
| Alarm modes | Upper value Lower value |
| Repeatability | ±1.8°C (±3.2°F) @ -50 ... 20°C (-31 ... 68°F) ±0.5% or ±0.5°C (±0.9°F) @ 20 ... 1000°C (68 ... 1832°F) |
| Emissivity from/to | 0.1 ... 1 |
| Spectral range | 8 ... 14 µm |
| Wavelength range | 630 ... 670 Nm |
| Menu language | English, English (GB) |
| Protection class (device) | IP54 |
| (Rechargeable) battery | 2 x 1,5 V AAA battery , Alkali-manganese |
| Capacity | 1270 mAh |
| Performance | 1,91 Wh |
| Operating conditions | 0 ... 50 °C , 10 ... 90 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 175 x 50 x 98 mm |
| Weight | 219 g |