The PCE-DC1 HVAC meter has been designed to detect, indirectly, AC/DC current and ohms. The clamp has white LEDs integrated to allow for the point of measurement to be illuminated, and a function to test the voltage without contact. The reduced dimensions of this device allow for measurements to be taken in places with limited access. The backlit display ensures that it is easy to read, even in places with limited light available, such as electrical cabinets or in cabling ducts. Testing voltage without contact helps when detecting dangerous power lines, and it allows makes it easier to detect the location of cuts in power lines.
AC current
(50/60 Hz) real effective value |
Sector / accuracy
200 AAC / ±2.5% + 8 digits |
DC current | Sector / accuracy
200 ADC / ±2.0% + 5 digits |
Testing AC voltage (50/60Hz) real effective value | 600 VAC ±(1.5% + 8 digits) |
Testing DC voltage | 600 VDC ±(1.5% + 2 digits) |
Ohms | 999.9 Ω ±(1.5% + 8 digits) |
Illumination of measurement point | White LEDs |
Diameter of the conductor | Maximum of 18 mm / 0.7 in |
Display | Backlit LCD with 3 2/3 positions |
Power | 2 AAA batteries |
Enclosure | PVC |
Dimensions | 164 x 65 x 32 mm / 6.4 x 2.5 x 1.2 in |
Weight | 175 g / < 1 lb |
Standards | EN61010-1; CAT II / 600V
EN61010-2-032; CAT III / 300V |
1 x PCE-DC2 HVAC meter
2 x Measurement cables
1 x Bag
2 x Batteries
1 x User's manual
1 x ISO Calibration Certificate
N.B. Calibration certificates are issued specifically for the customer and are excluded from the right of return.