Clamp on Tester

Order no.: CA-Y1N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 3%
- Transformer ratio (E:A): 1000 : 1

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN21

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Rated current: 200 A AC
- Transformation ratio: 1,000/1
- Output: lead and isolated Ø 4 mm male plugs
- Output protected against voltage surges

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN38

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Rated current: 200 A AC
- Output signal: AC voltage
- Output / input ratio: 100 mV / A AC, 10 mV / A AC
- Output: isolated Ø 4 mm female sockets

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN39

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Rated current: 200 A AC
- Output signal: AC voltage
- Output / input ratio: 100 mV / A AC, 10 mV / A AC
- Output: lead and isolated Ø 4 mm male plugs

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN60

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Output signal: AC voltage
- Output / input ratio: 100 mV / A AC, 10 mV / A AC
- Output: coaxial cable and isolated BNC male plug  

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C100

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN71

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Rated current: 10 A AC
- Output signal: AC voltage
- Output / input ratio: 100 mV / A AC
- Output: lead and isolated Ø 4 mm male plugs

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-Y4N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 2%
- Transformer ratio (E:A): 1 A : 1 mV DC

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C102

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket
- Output protected against voltage surges

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C103

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in male plugs

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-MN73

Clamp on Tester for multimeters, oscilloscopes and current faults, max. 200 A AC, max. Diameter 20 mm. The Clamp on Tester MN series offers 3 choices for the output. In addition to AC and AC voltage, a DC voltage output is possible from the Clamp on Tester. The test instrument is sent out manufacturer calibrated - a certification according to ISO standards is available optionally.


- Output signal: AC voltage
- Output / input ratio: 1,000 mV / A AC, 10 mV / A AC
- Output: lead and isolated Ø 4 mm male plugs

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C106

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C122

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 A ... 1000 A
- Transformer Ratio: 1000 / 5
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C107

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in plug
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C112

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 10 mA ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-Y3N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 3%
- Transformer ratio (E:A): 100 : 1

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C113

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 10 mA ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D33N

The CA-D33N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows for accurate AC current measurement even at currents up to 3000 A. Due to the rectangular shape, the D Series is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO certification as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA
- Connection: 4 mm / 1.6 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-Y7N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 1 A ... 500 A AC
- Accuracy: ≤2%
- Transformer ratio (E:A): 1 A : 1 mV AC

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D30N

The CA-D30N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer