Water Analyser

Water Analyser PCE-DRG 6
£ 260.00
Price excl. VAT &. delivery
Our Water Analyser determines the percentage of dimethylformamide in aqueous media with a measurement range of 0 to 55 %. The measurement result and the temperature of the sample are shown in two lines on the LCD display of the Water Analyser. The Water Analyser can measure various parameters such as percentage and refractive index quickly and accurately with just four to five drops of the sample.

  • dimethylformamide 0 ... 55 %
  • resolution: 0.1 %
  • accuracy: ±0.2 %
  • refractive index: 1.32600 ... 1.40390 nD
  • quick and accurate measurement in approx. 1 s
  • easy to use (1-key operation)
  • small sample volume
  • automatic temperature compensation
  • stainless steel sample holder with glass prism
Water Analyser PCE-DRG 7
£ 260.00
Price excl. VAT &. delivery
Our Water Analyser determines the percentage of dimethylformamide in water with a measurement range of 0 to 100 %. The measurement result and the temperature of the sample are shown in two lines on the LCD display of the Water Analyser. The Water Analyser can measure various parameters such as percentage and refractive index quickly and accurately with just four to five drops of the sample.

  • dimethylformamide 0 ... 100 %
  • resolution: 0.1 %
  • accuracy: ±0.2 %
  • refractive index: 1.32600 ... 1.43200 nD
  • quick and accurate measurement in approx. 1 s
  • easy to use (1-key operation)
  • small sample volume
  • automatic temperature compensation
  • stainless steel sample holder with glass prism
Water Analyser PCE-DRG 8
£ 260.00
Price excl. VAT &. delivery
Our Water Analyser determines the percentage of n-methyl-2-pyrrolidone in aqueous media with a measurement range of 0 to 100 %. The measurement result and the temperature of the sample are shown in two lines on the LCD display of the Water Analyser. Our Water Analyser can measure various parameters such as percentage and refractive index quickly and accurately with just four to five drops of the sample.

  • n-methyl-2-pyrrolidone 0 ... 100 %
  • resolution: 0.1 %
  • accuracy: ±0.2 %
  • refractive index: 1.32600 ... 1.48000 nD
  • quick and accurate measurement in approx. 1 s
  • easy to use (1-key operation)
  • small sample volume
  • automatic temperature compensation
  • stainless steel sample holder with glass prism
Water Analyser PCE-DRG 9
£ 260.00
Price excl. VAT &. delivery
Our Water Analyser determines the percentage of sodium hypochlorite in aqueous media with a measurement range of 0 to 18 %. The measurement result and the temperature of the sample are shown in two lines on the LCD display of the Water Analyser. Our Water Analyser can measure various parameters such as percentage and refractive index quickly and accurately with just four to five drops of the sample.

  • sodium hypochlorite 0 ... 18 %
  • resolution: 0.1 %
  • accuracy: ±0.2 %
  • refractive index: 1.32500 ... 1.40000 nD
  • quick and accurate measurement in approx. 1 s
  • easy to use (1-key operation)
  • small sample volume
  • automatic temperature compensation
  • stainless steel sample holder with glass prism
Water Analyser PCE-PH 228HTE
£ 566.00
Price excl. VAT &. delivery
The Water Analyser stands for precision, user-friendliness and GLP compliance. Good Laboratory Practice With a high-resolution LCD screen, the Water Analyser provides a clear and concise display of the measured values. GLP compliance is guaranteed by automatic data recording and traceable documentation.

  • measurement range -2 ... +20 pH
  • high accuracy ±0.002 pH + 2 digits
  • adjustable resolution: 0.1 pH, 0.01 pH, 0.001 pH
  • simple 2, 3, 4 and 5-point calibration
  • graphical display of the measurement process
  • GLP data management
  • data logger
  • pH electrode for higher temperatures up to 80 °C
Water Analyser PCE-PH 228LIQ
£ 608.00
Price excl. VAT &. delivery
The Water Analyser stands for precision, user-friendliness and GLP compliance. Good Laboratory Practice With a high-resolution LCD screen, the Water Analyser provides a clear and concise display of the measured values. GLP compliance is guaranteed by automatic data recording and traceable documentation. It is possible to measure the pH or redox value and temperature with external sensors.

  • measurement range -2 ... +20 pH (meter)
  • measurement range 0 ... 14 pH (electrode)
  • high accuracy ±0.002 pH + 2 digits
  • adjustable resolution: 0.1 pH, 0.01 pH, 0.001 pH
  • GLP data management
  • simple 2, 3, 4 and 5-point calibration
  • calibration reminder
  • graphical display of the measurement process
  • data logger
  • especially for beer, blood, dairy products
Water Analyser PCE-PH 228HTE-ICA incl. ISO-Calibration Certificate
£ 621.00
Price excl. VAT &. delivery
ISO Calibration
The Water Analyser stands for precision, user-friendliness and GLP compliance. Good Laboratory Practice With a high-resolution LCD screen, the Water Analyser provides a clear and concise display of the measured values. GLP compliance is guaranteed by automatic data recording and traceable documentation.

  • measurement range -2 ... +20 pH
  • high accuracy ±0.002 pH + 2 digits
  • adjustable resolution: 0.1 pH, 0.01 pH, 0.001 pH
  • simple 2, 3, 4 and 5-point calibration
  • graphical display of the measurement process
  • GLP data management
  • data logger
  • pH electrode for higher temperatures up to 100 °C
  • incl. ISO-Calibration Certificate
Water Analyser PCE-PH 228LIQ-ICA incl. ISO-Calibration Certificate
£ 656.00
Price excl. VAT &. delivery
ISO Calibration
The Water Analyser stands for precision, user-friendliness and GLP compliance. Good Laboratory Practice With a high-resolution LCD screen, the Water Analyser provides a clear and concise display of the measured values. GLP compliance is guaranteed by automatic data recording and traceable documentation. It is possible to measure the pH or redox value and temperature with external sensors.

  • measurement range -2 ... +20 pH (meter)
  • measurement range 0 ... 14 pH (electrode)
  • high accuracy ±0.002 pH + 2 digits
  • adjustable resolution: 0.1 pH, 0.01 pH, 0.001 pH
  • GLP data management
  • simple 2, 3, 4 and 5-point calibration
  • calibration reminder
  • graphical display of the measurement process
  • data logger
  • especially for beer, blood, dairy products